Installation guide
A Sample VLAN Topology
A Sample VLAN Topology
Chapter 7
66
Figure 7-5 RJ-45/DB-9 Console Adapter Cable
Shelf Manager Command Line Interface and Basic Commands
After connecting your terminal or laptop to a ShMM, login to the ShMM as root. The ShMM command line
interface prompt (clia) will appear on your terminal or laptop display. Use the ShMM command line interface
to enter the following basic ShMM commands and see how they work:
clia help This command gives you a list of all ShMM commands.
clia shmstatus This command tells you if this ShMM is the active ShMM, or the backup.
clia board -v This command tells information about the blade population in the shelf.
clia switchover This command causes the backup ShMM to become active, and forces the active ShMM to
reboot, and then go into backup mode.
clia boardreset 1 This command causes the blade in physical slot 1 to reboot. If there is no blade in slot 1,
the command has no effect.
If you want to learn more about specific ShMM commands, refer to the HP bh5700 ATCA 14-Slot Blade
Server, Shelf Manager User and Service Guide and the Shelf Manager External Interface User and Service
Guide.
Configuring eth0
In order to configure eth0 (the RMCP network adapter default IP address) on the ShMM, you must first
ensure that jumpers B141 to 144 on both ShMM carrier boards are installed in the back position (see
Figure 7-6 on page 67). This ensures that eth0 is ported to the 14-Slot Shelf backplane, and not to the ShMM
front panel. Complete the following steps to ensure these jumpers are installed as required:
Step 1. Remove the ShMM you are about to configure from the 14-Slot Shelf. See the HP bh5700 ATCA
14-Slot Blade Server, Maintenance Guide, Removal and Replacement Procedures document for
instructions on removing and reinstalling the ShMM.
CAUTION Observe all ESD safety precautions while completing this procedure. Failure to
follow ESD safety precautions could result in damage to the 14-Slot Shelf and
equipment.
Step 2. With the ShMM removed, ensure that jumpers B141 to B144 on the ShMM carrier board are
installed in the back position (toward the rear of the carrier board), as shown in Figure 7-6 on
page 67.