Installation guide
Installing 14-Slot Shelf Components
Installing 14-Slot Shelf Components
Chapter 5
44
Figure 5-2 Releasing the DIMM from DIMM Socket U5
Step 5. Grasp the memory module and remove by angling away from the socket. Place the DIMM in a
static-safe location.
Step 6. Repeat steps 4 and 5 to remove any remaining DIMMs. Place each memory module in a static-safe
location.
Replacing the Memory Modules
CAUTION Observe all ESD safety precautions while completing this procedure. Failure to follow ESD
safety precautions can result in damage to the 14-Slot Shelf and equipment.
CAUTION Each DIMM is keyed . Ensure the memory module is indexed correctly before seating into a
DIMM socket. Failure to observe will damage the DIMM and the socket, requiring replacement
of the Server Blade and the affected DIMM.