User manual

22
®
[Enable AUTO SEQ]
Choosing channel numbers from 1 to 4 and setting the tour intervals, the system will
display four channels’ video image in full screen in certain sequence, the detailed steps as following:
[1] Set the interval time. It’s the time interval between two channels’ full screen display
[2] Set channels of video tour sequencing. You can set the channel numbers as per your need.
[3] Click whether to go back to quad screen. When the check box is enabled, the system will go back to quad
screen rst and then continue sequencing after one tour of sequencing.
Click [
Save],
the setting will take effect immediately.
2.3.3.6 External Alarm
Click to enter alarm setting, as shown in gure 28:
Figure 28 External Alarm
Alarm setting steps are as follows:
[1] [Alarm In]
Choose the channel number of alarm input from all four channels, users can choose according
to their specic needs, check ON to turn on alarm input channel.
[2] [Type]
Choose the type of alarm from two options: Normally Open & Normally Close.
[3]
Check
[Alarm Out]
to set the alarm output, the device only support one channel alarm output, user can
also set the time of alarm delay ( up to 30secs)
[4] [Trigger Period]
iis for setting the alarm triggered period. Click [set] to set the alarm triggered period, user
can set the period of alarm triggered according to their specic needs.
[5] [Record Channel]
is for setting the channel of alarm triggered recording, the user can choose any channel
or all 4 channels for alarm triggered recording.
[6]
Choose the type of alarm, the device supports E-mail Alarm & Buzzer Alarm. Choose E-mail Alarm, then
emails will be sent to appointed email account when alarm is triggered. Choose Buzzer, then there will be
buzzer sound when alarm is triggered.
Click
[Save]
to save all the above settings.
2.3.3.7 Motion Detection Alarm