Owners Manual
98
Gas Connection
Gas Connection
Gas Connection
INSTALLATION
ROOM VENTILATION
An exhaust fan may be used with the appliance; in each case it shall be installed
in conformity with the appropriate national and local standards. Exhaust hood
operation may affect other vented appliances; in each case it shall be installed in
conformity with the appropriate national and local standards.
The use of a gas cooking appliance generates heat and humidity in the room where
it is installed. Proper ventilation in the room is needed. Make sure the kitchen is
equipped with a range hood of appropriate power (400 CFM minimum). Activate
the exhaust fan/range hood when possible. Intensive and continuous use of the
appliance may require additional ventilation, for example, by opening a window.
TYPE OF GAS
This appliance is shipped from the factory for use with natural gas. For use with
propane LP gas, please follow the conversion procedure described on pg. 18. A step
by step conversion procedure is also included with each set of LP gas nozzles.
GAS PRESSURE
The maximum inlet gas supply pressure incoming to the gas appliance pressure
regulator is 34PSI (13,8w. cpr 3,5kPA).
The minimum gas supply pressure for checking the regulator setting shall be at least
1˝ w.c (249 Pa) above the inlet specified manifold pressure to the appliance (This
operating pressure is 4˝ w.c. (1.00kPa) for Natural gas and 11˝ w.c. (2.75 kPa) for
LP gas.
Gas cooktop requires 1”- 6” side wall spacing above the counter height for proper
combustion. Please review specific model installation instructions for required dimen-
sions. 30 inches between the cooktop and bottom of the cabinet above. 0.25 inches
for sides below countertop height.
NOTE: Please consult your local building codes for variations with installation.
INSTALLATION
Gas Connection
• All gas connections must comply with national and local codes. The gas supply
line (service) must be the same size or greater than the inlet line of the appliance.
This range uses a ½˝ NPT inlet. Use appropriate sealant on all pipe joints that
are resistant to gas.
• This range can be used with Natural or LP/propane gas. The range is shipped
from the factory for use with natural gas.
• For LP/Propane household installation, the appliance must be converted by the
dealer, factory-trained professional, or qualified licensed plumber or gas service
company.
• Gas conversion is important for safe and effective use of the appliance. It
is the responsibility of the dealer and the owner of the range to perform the
appropriate gas conversion following the directions of the manufacturer.
• The gas conversion procedure is described in this manual and in the package
containing the conversion nozzles shipped with every range.
Please provide the service person with this manual before work is started on the
range.
DO NOT use an open flame when checking for leaks.
Leak testing of the appliance shall be conducted according to the manufacturer’s
instructions. Before operating the appliance, always check for leaks with soapy
water solution or other acceptable method. Check for gas leakage with soapy
water solutions on all gas connections between inlet gas pipes of the appliance, the
gas regulator and, the manual shut-off valve. Bubbles will form with a soapy water
solution if there is a leak.
WARNING