Owners Manual
1514
Gas Conversion Procedure
INSTALLATION
Gas Conversion Procedure
STEP 2: SURFACE BURNERS
To replace the nozzles of the surface burners, lift up the burners and unscrew the
nozzles shipped with the range using a 7 mm (socket wrench).
Replace nozzles using the conversion set supplied with the range. Each nozzle has a
number indicating its flow diameter printed on the body. Consult the table on page 12
for matching nozzles to burners.
NG = Natural Gas
LPG = Liquid Propane Gas
NG LPG
9/32
9/32
Step1
Step 2
Step 3
Step 4
Step 5
STEP 3: FLAME ADJUSTMENT
1. Light one burner at a time and set it to the MINIMUM position (small flame).
2. Remove the knob.
3. The range is equipped with a safety valve. Using a small-size flathead
screwdriver, locate the choke screw (see diagram below) and turn to the right or
left until the burner flame is adjusted to desired minimum.
4. Make sure that the flame does not go out when switching quickly from the
MAXIMUM to the MINIMUM position.
The high flame setting cannot be adjusted to be lower. If the height is too high, revisit
the conversion set up. A step may have been missed.
INSTALLATION
Flame Adjustment
WIRING DIAGRAM
DW7714-18 & DW7713-24
18” & 24“ Panel-Ready Dishwasher
0.0.0.
FLAME ADJUSTMENT
Germania
RA series, RG series
zlinekitchen.com 1-614-777-5004 0.0.0.zlinekitchen.com 1-614-777-5004
2.0 x 50 mm
2.0 x 50 mm
If the customer flame control valve looks like this (left), then they will not be able to adjust the
flame without removing one of the screws. These new ranges are already fielded, so please
do not process returns for this issue. The valves are different from the previous ones and are
not interchangeable.
SCAN ME SCAN ME
2.0 x 50 mm
2.0 x 50 mm
Flame Adjustment