User Manual
10
The appliance shall be connected to a single phase electric line rated at 110-120Vac 
and 60Hz frequency. The true voltage in most homes is usually between these values.
Electric Power Rating
220/240 Vac: 12A Max
If voltage is less than 220/240, then preheat times may vary. 
Heating Element Power Rating
Electric Model:
Oven Bake (Electric): 1500 Watts
Oven Broil (Electric): 2850 Watts 
Oven Circ. Element: 3200 Watts
Install suitable electric power supply receptacle connection type NEMA 14-50R able 
to support a load of at least 30 A (Per Line) according to local code requirements. 
For four wires power supply connection system (see diagram below).
Electrical Grounding
Our oven is equipped with a four-prong plug for your protection against shock 
hazard and should be plugged directly into a properly grounded receptacle. Do not 
cut or remove the prong from this plug. 
Power Rating & Electrical Connection
L2 (red)
N (white)
G (green)
L1 (black)
L2 (red)
N (white)
G (green)
L1 (black)
cable from 
power supply
Four-Wire Connection 
Receptacle
NEMA 14-50R
Disconnect electrical power at the circuit breaker box or fuse box 
before installing the appliance. 
Provide appropriate ground for the appliance. Use copper 
conductors only. 
WARNING