User Manual
4
Room Ventilation
An exhaust fan may be used with the appliance; in each case it shall be installed 
in conformity with the appropriate national and local standards. Exhaust hood 
operation may affect other vented appliances; in each case it shall be installed in 
conformity with the appropriate national and local standards.
Type of Gas
This appliance is shipped from the factory for use with natural gas. For use with 
propane LP gas, please follow the conversion procedure described on pg. 18. A step 
by step conversion procedure is also included with each set of LP gas nozzles.
Gas Pressure
The maximum inlet gas supply pressure incoming to the gas appliance pressure 
regulator is 34PSI (13,8w. cpr 3,5kPA). 
The minimum gas supply pressure for checking the regulator setting shall be at least 
1˝ w.c (249 Pa) above the inlet specified manifold pressure to the appliance (This 
operating pressure is 4˝ w.c. (1.00kPa) for Natural gas and 11˝ w.c. (2.75 kPa) for 
LP gas.
Before Installation
Gas cooktop requires 1”- 6” side wall spacing above the counter height for 
proper combustion. Please review specific model installation instructions for 
required dimensions. 30 inches between the cooktop and bottom of the cabinet 
above. 0.25 inches for sides below countertop height. 
NOTE: Please consult your local building codes for variations with installation.