This appliance shall only be installed by an authorized professional. 
The appliance shall be installed in accordance with the standards of the country 
where it will be installed. The installation of this appliance must conform to local 
codes and ordinances. In the absence of local codes installation must conform to 
American National Standards, National fuel Gas code ANSI Z223.1-Latest edition/
NFPA 54 or B 149.1.
The appliance, when installed, must be electrically grounded in accordance with 
local codes or, in the absence of local codes, with the National Electrical code, 
ANSI/NFPA 70.
If local codes permit, a flexible metal appliance connections with the new AGA or 
CGA certified design, max 5 feet (1.5m) long, 34˝m is recommended for connecting 
this appliance to the gas supply line. DO NOT bend or damage the flexible 
connector when moving the appliance. 
This appliance must be used with the pressure regulator provided. The regulator must 
be properly installed in order to be accessible when the appliance is installed in 
its final location. The pressure regulator must be set for the type of gas to be used. 
The pressure regulator has 34˝ female pipe thread. The appropriate fitting must be 
determined based on the size of your gas supply line, the flexible metal connector 
and the shut-off valve. 
The appliance must be isolated from the gas supply piping system by closing its 
individual manual shut-off valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 34 PSI(13,8w.cpr 3,5kPA). 
All opening holes in the wall and floor, back and under the appliance shall be sealed 
before installation of the appliance. 
A manual valve shall be installed in an accessible location in the gas line external to 
the appliance for the purpose of turning on and shutting off the gas to the appliance.