9.1 Access Control Options
To set the parameters of the control lock of the terminal and related equipment.
Click Access Control Options on the Access Control interface.
Item Description
Gate control mode
★
Whether to turn on the gate control mode or not, when set to ON, on this interface will
remove Door lock relay, Door sensor relay and Door sensor type function.
Door Lock Delay (s)
The length of time that the device controls the electric lock to be unlock. Valid value:
1~10 seconds; 0 second represents disabling the function.
Door Sensor Delay
(s)
If the door is not closed and locked after opening for a certain duration (Door Sensor Delay), an
alarm will be triggered. The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
Door Sensor Type
There are three types: None, Normal Open, and Normal Close. None means door sensor is not in
use; Normal Open means the door is always opened when electricity is on; Normal Close
means the door is always closed when electricity is on.
Door Alarm Delay
(s)
When the state of the door sensor is inconsistent with that of the door sensor type, an alarm will
be triggered after a specified time period, i.e. the Door Alarm Delay. The valid value ranges from
1 to 999 seconds. 0 means immediate alarm.
Retry Times to
Alarm
When the number of failed verification reaches a set value, which ranges from 1 to 9
times, an alarm will be triggered. If the set value is “None”, the alarm will never be