Installation Guide FR1500S Version: 1.0 Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
Installation Dimensions(mm) 38.0 7.1 121.3 77.3 Note: Not all the devices have the fingerprint cover. The real product prevails.
Installation STEP 2 Take out the front panel as shown below Method 1: Mounting on the standard Single gang junction box Lay the cables from the desired hole in Single gang junction box and fix the machine part to the box part. The Single gang junction box's size recommendations: Location column: 83.3mm Inside of the box Depth: Minimum 36mm Outside the box size: maximum length 120mm , maximum width 76mm m 83.
Method 2: Mounting inside the wall STEP 1 Place the mounting sticker to the place where device needs to be installed STEP 2 Drill fixing holes and dig mounting groove deep of 36mm wall Fixing Hole The depth of the installation groove is 36mm 36m Instruction for the Mounting Paper Before the device is fastened, please stick the paper to the place where you want to install it, then make holes and lay cables according to the mounting paper.
Wiring Terminals This reader is an innovative Silk ID reader. It needs to be connected to a host machine so that fingerprint information can be transferred through Rs485. Reader wires nomenclature and Dip Switch Dip Switch RED 12V BLACK GND YELLOW 485+ PURPLE 485BLACK GND 1. Connection with a Control Panel. EXT SWITCH PWR STATE EXT RS485 +12V GND 485485+ PC RS485 + + - + - DC12V - DC12V so on......
Working Principle > Dip Switch setting with control panel Address Switch Setting Address Switch Setting Terminal Resistance 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 8 4 2 1 6 2 1 2 3 4 5 6 7 3 1 2 3 4 5 6 8 4 1 2 3 4 5 6 Number 1, 2, 3, 4 of the dip switch are used to set the address of RS485, 5 is the restart switch, and 6 is the Terminal Resistance. Number 5 is the restart switch: dial up and dial down.
+12V GND GND 485A 485B 2. Connection with a Standalone Access Controller 1 +12V GND +12V GND 4 1 GND GND 485A 485+ 485- 4 85B 5 When using the reader with Standalone access controller device, please move the dial code “1” to the ON position as shown above.
Verification Proccess Connection with the controller: Unsuccessful: LED flashes blue light twice every one second. Successfully: LED flashes blue light once every one second.
FCC warning: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.