User manual
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
complete adding. The added personnel will appear in the list on the right;
(3) Select personnel, click [Delete from Access Level] to delete the personnel from the access level.
Note: When adding personnel, if selected personnel exist in the current access level, the system cannot them add again.
2. Edit Access Level for Personnel:
(1) Click [Access Control System] - [Personnel Access Level Settings] - [Shown by Personnel] interface, click a person, and
the list on the right will show the access level of that person;
(2) Click [Add Access Level] to open the edit interface, select access level, and click [OK] to complete editing. The list on the
right will show the access level;
(3) Select access level and click [Delete Access Level] to delete the person from the access level.
6.6 Real-time Monitoring
Monitor the statuses and real-time events of doors under the access control panels in the system in real-time, including normal
events and exceptional events (including alarm events).
1. Monitoring All:
The system will, by default, show the monitoring of all doors under the control panels within the current user’s access level.
The user can monitor one (or more) doors by [Area], [Control Panel] or [Door].
Remote Opening/Closing: Including the operations of single door and all current doors. In single door operation, move the
cursor to the door icon, click [Remote Opening/Closing] in the popup menu. In all current doors operation, click [Close All
Current Doors] in the main interface to fulfill the operation.
When you remote close the door, the open time interval is enabled15 seconds by default. You can select [Enable Intraday
Normal Open Time Zone], and the Normal Open Time Zone Intraday will take effect. You can also set the door state to Normal
Open directly, and no time zone intraday can affect the door state any more (namely normally open for 24 hours).
If you want to close the door, select [Disable Intraday Normal Open Time Zone] first to avoid other normal open time zones
taking effect and opening the door. Then select [Remote Closing] to complete the operation.
Note: If the operations of remote opening/closing always return failure, please check the current list of devices. If there
are too many offline devices, you need to check the network to ensure the operation progressed normally.
Cancel all alarms: Once alarming doors appear on the interface, the system will alarm. Click to cancel the alarms of the
control panels for alarming doors. If Cancel Alarms is successful, the system will automatically stop alarming.
Note: If a control panel has multiple door alarms at the same time, you only need to execute one cancel operation at one
of these doors to cancel all the alarms in this control panel.