Enter the old communication password before modification. After verification, input the same new password twice, and click
[OK] to modify the communication password.
Note: The communication password cannot contain spaces, it is recommended that a combination of numbers and
letters be used. The communication password setting can improve the device security. It is recommended to set
communication password for each device.
(5) Synchronize Time:
Synchronize device time with current server time.
(6) Get Event Entries:
Get event records from the device into the system.
Three options are provided for this operation, Get New Entries, Get All Entries, and Get Entries from SD Card.
Get New Entries: The system only gets the new event entries since the last time event entries were collected and records
them into the database. Repeated entries will not be rewritten.
Get All Entries: The system will get all of the event entries again. Repeated entries will not be rewritten.
Get Entries from SD Card: The system will get the event entries from the SD card in the device.
When the network status is normal and the communication status between the system and the device is normal, the system
will acquire event records in the device in real-time and save them into the system database. However, when the network is
interrupted or communication is interrupted for any reason and the event records in the device have not been uploaded into
the system in real-time, the operation can be used to manually acquire event records in the device. In addition, the system, by
default, will automatically acquire event records in the device at 00:00 each day.
Note: The access controller can restore up to 100 thousand event entries. When the entries exceed this number, the
device will automatically delete the oldest stored entries (the default delete number is 10 thousand).
(7) Upgrade Firmware
To upgrade firmware in the device, tick the device for which you want to upgrade the firmware, click [Upgrade firmware], enter
edit interface, click [Browse] to select the firmware upgrade file (named emfw.cfg) provided by ZKAccess, and click [OK] to
start upgrading.
Note: The user shall not upgrade firmware without authorization. Contact the distributor before upgrading firmware, or
upgrade it when instructed by the distributor. Unauthorized upgrading may cause problems that affect normal use.
(8) Change the fingerprint identification threshold (only available for version 5.0.8 and above)
The user can change the fingerprint identification threshold in the device. The scale is 35-70 and 55 by default. In device
adding, the system will get the threshold from the device. If the operation succeeds, the user can view the threshold in all of
the devices. Batch operation is permitted; the user can change multiple devices concurrently.
(9) Enable Daylight Saving Time
Select the Daylight Saving Time being set, click [Enable Daylight Saving Time] to enable it.
(10) Disable Daylight Saving Time
Disable the Daylight Saving Time in use.
(11) Get Information of Personnel
Renew the current number of personnel and fingerprints in the device. The final value will be displayed on the device list.
(12) Close Auxiliary Output
Close the auxiliary device connected to the device auxiliary output interface.
2. Door Management:
The device list will show all access control devices. Click the “+” button before the device name to show the door list under a
device. When adding a device, it will automatically add doors (corresponding device name and door numbers cannot be edited)