User manual
3.2.4 Unlocking Combination settings
Combo settings are for extra added security, where more than ons user need to sign in
before access is granted.
3.2.5 Change Access Control Parameters settings
Summary
* Combo settings for
added security
* 2 or more user verifi ca-
tion needed before access
allowed
* Parameter settings is to
change the control of the
unit
12
• Press to select UNLOCK COMB SETTINGS
• Press
• Press (menu) for NEW / EDIT / DELETE op-
tions
• Press to select ACCESS CONTROL SETTINGS
• Press
• Press to select fi eld and change values
•
Press to select ACCESS CONTROL SETTIN
GS
•
Press to select field and change values
• Lock (1-10s) :
To adjust the unlocking time after verifi cation.
• Dsen. Delay (1-99s) :
To delay door sensor from triggering alarm
system when door is not closing. This function
only works when a door sensor is attached to
the reader.
• Dsen Mode :
To choose the type of door sensor attached to
the reader. There are NO (normally opened)
and NC (normally closed) available. Choose
NONE if no door sensor is attached.
• Alarm Delay (1-99s) :
To delay the reader from triggering alarm
system.
• Alarm count (1-9 ti mes ) :
To adjust the maximum verifi cation failures of
users. When the maximum is reached, reader
will trigger alarm system.
• Close TZ :
Door is always locked during the predefi ned
time period, so users cannot gain access after
verifi cation.
• Open TZ :
Door is always unlocked during the predefi ned
time period, so users do not need to verify their
identities but can gain access.
• Valid holidays :
Choose Valid to enable the holiday settings.
Choose Invalid to disable the holiday settings.
• Press to save.