User Manual

1.6 SPECIFICATIONS
INPUT CHARACTERISTICS: S1M-6460P
l VOLTAGE: 90~264VAC FULL RANGE
l FREQUENCY:47~63HZ
l INPUT CURRENT: 4A ( RMS ) FOR 230VAC
8A ( RMS ) FOR 115VAC
l INRUSH CURRENT : 60 A MAX.FOR 115 VAC PER MODULE
80 A MAX. FOR 230 VAC PER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT REGULATION OUTPUT
MIN. [A] MAX. [A] LOAD LINE
+5V 1 32
±
5%
±
1%
70mV
+12V 2 32 ±
5%
±
1%
120mV
-12V 0 1
±
5%
±
1%
120mV
+3.3V 1 30
±
5%
±
1%
70mV
+5VSB 0.1 2.0
±
5%
±
1%
70mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: 1.TOTAL CURRENT OF +5V AND +3.3V NOT EXCEED 50A
2.TOTAL OUTPUT POWER NOT EXCEED 440W
SPECIFICATION:
l TEMPERATURE RANGE: OPERATING 0 --- 40,STORAGE -20 --- 70
l HOLD UP TIME: 1.6 ms MINIMUM AT FULL LOAD & 90VAC INPUT VOLTAGE
l DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
l EFFICIENCY: 67% TYPICAL, AT FULL LOAD
l POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l OVER LOAD PROTECTION: 110~160% MAX
. OVER VOLTAGE PROTECTION: +5V à 5.7V ~ 6.5V, +3.3V à3.9V~4.7V,+12V à 13.3V ~ 14.3V
. OVER CURRENT PROTECTION
l EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
l SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l REMOTE ON / OFF CONTROL
l FAULTY ALARM METHODS:LED, BUZZER, TTL SIGNAL
l MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC)
l HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
l REMOTE SENSING DESIGN
l ISOLATION:BUILT-IN THE POWER MODULE
l COOLING: TWO 40x40x28mm DC FANS
l AC INLET IN EACH MODULE
l DIMENSION:247.9x106x40(D*W*H)mm