PRODUCTS MANUAL ARx ADVANCED REDUNDANT POWER SUPPLY PART NO.
INDEX 1.1 INTRODUCTION-------------------------------------1 1.2 PACKING-----------------------------------------------1 1.3 DRAWING----------------------------------------------1-26 1.4 FEATURES---------------------------------------------27 1.5 SPECIFICATION--------------------------------------28-29 1.6 INSTALLATION AND TESTING------------------30 1.7 HOT-SWAP PROCEDURE--------------------------31 1.8 PINOUTS AND FUNCTION OF THE CONNECTORS----------------------------------------32 1.
1.1. INTRODUCTION Thank you for the purchase of the Advanced Redundant Switching Power System ARX (X may stand for D/I/H),each model has the same main structure and functions. The difference is on the shape and dimension. For each detail drawing, please refer to the section 1.
INPUT CHARACTERISTICS: ARD / I – 2/4/6400F VOLTAGE: 90 – 132 VAC / 180 ~ 264 VAC SWITCHABLE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 5.0 / 2.5A FOR 115 / 230 VAC PER POWER MODULE ( PARALLEL ) INRUSH CURRENT: 50A / 100A MAX. FOR 115 / 230 VAC OUTPUT CHARACTERISTICS: OUTPUT CURRENT OUTPUT VOLTAGE MIN.[A] MAX.[A] 20~36 REGULATION OUTPUT PEAK(A) LOAD LINE RIPPLE & NOISE MAX. [P-P] 40 ± 5% ± 1% 60mV 5V** 7.0 12V** 2.5 17 20 ± 8% ± 1% 120mV -5V*** 0 0.
INPUT CHARACTERISTICS: ARD / I – 2/4/6300F VOLTAGE: 90 – 132 VAC / 180 ~ 264 VAC SWITCHABLE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 5.0 / 2.5A FOR 115 / 230 VAC PER POWER MODULE ( PARALLEL ) INRUSH CURRENT: 50A / 100A MAX. FOR 115 / 230 VAC OUTPUT CHARACTERISTICS: OUTPUT CURRENT OUTPUT VOLTAGE MIN.[A] MAX.[A] 20~36 REGULATION OUTPUT PEAK(A) LOAD LINE RIPPLE & NOISE MAX. [P-P] 40 ± 5% ± 1% 60mV 5V** 7.0 12V** 2.5 17 20 ± 8% ± 1% 120mV -5V*** 0 0.
1.4. FEATURES REDUNDANCY HOT-SWAP FUNCTION BUZZER POWER DEFECTIVE SIGNAL LEDS HOT-PLUGGABLE FUNCTION SAFETY RELIABILITY COMPATIBILITY Independent DC Outputs and passive backplane design ensure redundant function been performed for computer system. Balance Share loading with no transfer time when backup takes place. The power system provides a HOT-SWAP function.
1.6. INSTALLATION & TESTING Turn off (remote off) the on / off switch. Mount the power supply in the system chassis using the proper mounting hardware, the mounting holes in the power supply should match up with those in the case. Attach the connectors to the motherboard by following the motherboard’s instructions, there are various on connectors/pinouts in both the power supply and motherboard. They should match each other; otherwise the connection will cause undetectable harms.
If everything works out fine, then turn off (remote off) the power system, now put back the cover of the case and tighten then with the screws which you have retained earlier. Now you have completed the installation of the ARX redundant power supply system. 1.7. HOT-SWAP PROCEDURES Please refer to the following when either one-power module found defective. A) Locate the defective power module by examining the individual LED or the LED on the front control panel.
1.8.
2 WHITE SCL 1.9. TROUBLE SHOOTING If you have followed these directions correctly, there should be no problem. Same common symptoms are: the system doesn’t work, buzzer sound, work for a very short period, etc., please try the following steps to verify and correct it: 1. Check all the connections (correct pinouts, loose connections, wrong direction, etc.) 2. Check for short-circuits or defective peripherals by unhooking each peripheral once at a time.
The “RELIABILITY “ solution to E-application 新巨企業股份有限公司 ZIPPY TECHNOLOGY CORP. POWER DIVISION HEADQUARTERS 10F, NO. 50, MIN CHYUAN RD., SHIN-TIEN CITY, TAIPEI HSIEN, TAIWAN, R.O.C. TEL: 886-2-29188512 WEB SITE: http://www.zippy.com.tw FAX: 886-2-29134969 E-mail:power@zippy.com.tw USA OFFICE U.S. East (Atlantic) 11 Melanie Lane, Unit 1B East Hanover, NJ 07936 TEL:1-973-463-9499 FAX:1-973-453-8014 E-mail:edward@zippy.com U.S.