MODEL : MRG-5800V4V REPORT NO. : 10090203
9
3.1.3 Conducted Powerline Emission Limit
Maximum RF Line Voltage dB(uV)
Frequency Class B
MHz QUASI-PEAK AVERAGE
0.15 - 0.50 66-56 66-56
0.50 - 5.0 56 56
5.0 - 30 60 60
Remarks : In the Above Table, the tighter limit applies at the band edges.
3.1.4 EUT Configuration on Measurement
The equipment's which is listed 3.2 are installed on Conducted Power Line Test to meet the
Commission requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
3.1.5 EUT Exercise Software
The EUT exercise program used during conducted testing was designed to exercise the EUT in a
manner similar to a typical use. The exercise sequence is listed as below :
3.1.5.1 Setup the EUT and simulators as shown on 3.2.
3.1.5.2 Turn on the power of all equipment's.
3.1.6 Conducted Emission Data
The measurement range of conducted emission which is from 0.15 MHz to 30 MHz was
investigated. The initial step in collecting conducted data is a spectrum analyzer peak scan of the
measurement range for all the test modes. Then the worst modes were reported the following data
pages.