Datasheet

MODEL : MRG-5800V4V REPORT NO. : 10090203
21
5.3 Severity Levels
LEVEL FIELD STRENGTH V/M
1 1
2 3
3 10
X SPECIAL
5.4 EUT Operating Condition
Same as section 4.4.
5.5 Test Procedure
The EUT and load are placed on a table which is 0.8 meter above ground. The field sensor is
also placed on the same table to monitor field strength from transmitting antenna.
EUT is set 1 meter away from the transmitting antenna which is mounted on an antenna each
time.
The antenna is fixed 1 meter above ground. Both horizontal and vertical polarization of the
antenna are set on measurement. In order to judge the EUT performance, a CCD camera is
used to monitor EUT screen.
All the scanning conditions are as follows :
Condition of Test Remarks
1. Field Strength 3 V/M Level 2
2. Radiated Signal 80% Amplitude Modulated with a 1KHz Tone
3. Scanning Frequency 80 MHz-1 GHz
4. Sweep Time of Radiated 0.0015 Decade/s
5.6 Test Method
According to IEC 61000-4-3