MODEL : MRG-5800V4V REPORT NO. : 10090203
18
4.3 Severity Levels
LEVEL
TEST VOLTAGE CONTACT
DISCHARGE
TEST VOLTAGE AIR
DISCHARGE
1 2KV 2KV
2 4KV 4KV
3 6KV 6KV
4 8KV 8KV
X SPECIAL SPECIAL
4.4 EUT Operating Condition
1. Setup the EUT and Test Equipment as shown on 4.2
2. power on.
4.5 Test Procedure
Air Discharge:
This test was done above a non-conductive surfaces. The round discharge electrode about 30cm
away will approach as fast as possible to touch test points of the EUT.
Discharge happens before the contact. This procedure is repeated ten times on one selected location.
4.6 Test Method
According to IEC 61000-4-2