Datasheet

PAGE 2
ZIPPY EMC LAB
conduction test
EUT:
Manuf:
Op Cond:
Operator:
Test Spec:
Comment:
MRG-5800V4V SPS
ZIPPY TECH CO..LTD
FULL LOAD
EDMENT
EN 55022-- Class B
Load Condition( 50 21 0.8 19 3.5 )
N220V
Scan Settings
Frequencies Receiver Settings
Start Stop Step IF BW Detector M-Time Atten Preamp OpRge
(3 Ranges)
150kHz 500kHz 2kHz 10kHz QP+AV 1msec Auto OFF 60dB
500kHz 5MHz 20kHz 10kHz QP+AV 1msec Auto OFF 60dB
5MHz 30MHz 50kHz 10kHz QP+AV 1msec Auto OFF 60dB
Transducer No. Start Stop Name
1 9kHz 30MHz CEB
Meas Time:
Peaks:
Acc Margin:
Prescan Measurement: Detectors: X QP / + AV
see scan settings
8
25 dB
Peak Search Results
* limit exceeded
Indicated Phase/PE shows Configuration of max. Emission
Frequency
MHz
QP Level
dBµV
QP Limit
dBµV
QP Delta
dB
Phase
-
PE
-
0.206 53.34 63.37 10.03 N gnd
0.274 48.44 61.00 12.56 N gnd
0.344 45.85 59.11 13.26 N gnd
0.412 43.08 57.61 14.53 N gnd
0.48 40.97 56.34 15.37 N gnd
29.4 42.42 60.00 17.58 N gnd
29.6 41.45 60.00 18.55 N gnd
29.95 43.72 60.00 16.28 N gnd
Frequency
MHz
AV Level
dBµV
AV Limit
dBµV
AV Delta
dB
Phase
-
PE
-
0.206 49.00 53.37 4.37 N gnd
0.276 43.95 50.94 6.99 N gnd
0.342 42.05 49.15 7.10 N gnd
0.348 39.68 49.01 9.33 N gnd
0.41 39.41 47.65 8.24 N gnd
0.478 37.08 46.37 9.29 N gnd
0.484 36.15 46.27 10.12 N gnd
19.45 40.15 50.00 9.85 N gnd