Datasheet

PAGE 2
ZIPPY EMC LAB
conduction test
EUT:
Manuf:
Op Cond:
Operator:
Test Spec:
Comment:
MRG-5800V4V SPS
ZIPPY TECH CO..LTD
FULL LOAD
EDMENT
EN 55022-- Class B
Load Condition( 50 21 0.8 19 3.5 )
L220V
Scan Settings
Frequencies Receiver Settings
Start Stop Step IF BW Detector M-Time Atten Preamp OpRge
(3 Ranges)
150kHz 500kHz 2kHz 10kHz QP+AV 1msec Auto OFF 60dB
500kHz 5MHz 20kHz 10kHz QP+AV 1msec Auto OFF 60dB
5MHz 30MHz 50kHz 10kHz QP+AV 1msec Auto OFF 60dB
Transducer No. Start Stop Name
1 9kHz 30MHz CEB
Meas Time:
Peaks:
Acc Margin:
Prescan Measurement: Detectors: X QP / + AV
see scan settings
8
25 dB
Peak Search Results
* limit exceeded
Indicated Phase/PE shows Configuration of max. Emission
Frequency
MHz
QP Level
dBµV
QP Limit
dBµV
QP Delta
dB
Phase
-
PE
-
0.206 54.01 63.37 9.36 N gnd
0.276 49.28 60.94 11.66 N gnd
0.344 46.91 59.11 12.20 N gnd
0.414 44.13 57.57 13.44 N gnd
0.482 42.46 56.30 13.84 N gnd
29.2 41.76 60.00 18.24 N gnd
29.75 44.58 60.00 15.42 N gnd
29.95 41.85 60.00 18.15 N gnd
Frequency
MHz
AV Level
dBµV
AV Limit
dBµV
AV Delta
dB
Phase
-
PE
-
0.206 49.40 53.37 3.97 N gnd
0.276 45.08 50.94 5.86 N gnd
0.344 42.73 49.11 6.38 N gnd
0.412 41.15 47.61 6.46 N gnd
0.482 40.13 46.30 6.17 N gnd
0.488 37.08 46.20 9.12 N gnd
18.85 39.86 50.00 10.14 N gnd
19.25 39.51 50.00 10.49 N gnd