Installation guide
15 Confi gure your alarm widget and automation rules with the newly
added functionality!
3.1 ZONE WIRING Z1Z6
Zones can be wired as normally closed loops, with single (SEOL)
or double end-of-line (DEOL) resistors. For maximum protection,
use SEOL and DEOL confi gurations. Make sure not to exceed 400m
maximum wire length per zone.
NORMALLY CLOSED LOOP
Zone
terminal
COMMON
Zone
terminal
COMMON
One or more
normally
closed
contacts with
no end-of-
line resistor
SINGLE ENDOFLINE RESISTOR
Zone
terminal
COMMON
Zone
terminal
COMMON
One or more
normally
closed
contacts and
one or more
normally
opened
contacts with
end-of-line
resistor
DOUBLE ENDOFLINE RESISTOR
Zone
terminal
COMMON
Tamper
contact
Tamper
contact
Alarm
contact
One normally closed ALARM contact and one or
more normally closed tamper contacts with double
end-of-line resistor
3.2 OPTICALLY ISOLATED INPUT IN+/IN
Connect a device that provides voltage output of 8-14 V
DC
, with
positive wire going to terminal marked IN+ and negative wire going
to IN-. This input will consume no more than 40mA of current, and
has an internal 1kΩ termination resistor (so this input can be used
to interface Security module with existing alarm panel siren output).
make your home smart www.zipato.com make your home smart www.zipato.com
TRADEMARKS
Zipato and the Zipato logo are registered Trademarks. All
other product names mentioned herein may be trademarks or
registered trademarks of their respective companies.
NOTICE
Although Zipato has attempted to ensure the accuracy of the
content of this manual, it is possible that this document may
contain technical inaccuracies, typographical, or other errors.
Zipato assumes no liability for any error in this publication, and for
damages, whether direct, indirect, incidental, and consequential
or otherwise, that may result from such error, including, but not
limited to loss of data or profi ts. Zipato provides this publication
“as is” without warranty of any kind, either express or implied,
including, but not limited to implied warranties of merchantability
or fi tness for a particular purpose. The published information in
the manual is subject to change without notice. Zipato reserves
the right to make changes in the product design, layout, and driver
revisions without notifi cation to its users. This version of the
Installation guide supersedes all previous versions.
ELECTROMAGNETIC COMPATIBILITY
In proper state and when operated properly, the product complies
with all the requirements in respect of interference radiation
according to EN 301 489-17, EN 301 489-1 and EN 300 328. The
connections conducting HF signals must neither be manipulated
nor damaged.
TAKE CARE OF YOUR SAFETY
Display extreme caution when using ladders or steps, please
follow manufacturer’s instructions. Be careful when using hand
and power tools and follow the manufacturer’s guidelines when
using them. Take care that the correct tools are used. Wear
goggles or protective clothing where required.
DANGER
RISK OF ELECTROCUTION
All work on the device should only be carried out by trained and
skilled electricians. Observe the country-specifi c regulations.
CAUTION
The connected devices and the fl ush-mounted receiver can
become damaged if devices are operated that do not correspond
to the technical specifi cations (see technical data).
DANGER
RISK OF FATAL INJURY FROM ELECTRIC CURRENT.
The device has no basic insulation and must therefore be installed
in a way that protects against accidental contact.
DANGER
RISK OF FATAL INJURY FROM ELECTRIC CURRENT.
When installing a wall plate, the distance between the cover’s fi xing
brackets or screws and the connections of the fl ush - mounted MM
Switch Single must be at least 4 mm once installed. If the distance is
less than 4 mm, a deeper installation box must be used. The fi xing
brackets or screws of the cover must not press against the housing.
Only insulated tools may be used for operation on the device, e.g. an
insulated phase tester.
2.0 SPECIFICATIONS
TEMPERATURE RANGE 0 - 50ºC
HUMIDITY RANGE 0-95% RH
POWER powered by Zipabox
AUX POWER 10-14 V
DC
800mA
BELL/SIREN OUT 10-14 V
DC
600 mA
SIREN IN 8-14V
DC
, 20mA max
PGM OUT 150mA max solid state relay with selectable
active level (see 3.5)
3.0 INSTALLATION NOTES
01 Power off you Zipabox
02 Connect security module to either left or right side of the Zipabox
(if using Zipato Power or Backup module, Security module
connects after those modules).
Security module connected directly to Zipabox
Security module connected to Power module connected to Zipabox
03 Connect your wired sensors to Zone1-6.
04 Connect output from you existing panel or some external sensor
to terminals marked IN+/IN-.
05 Connect your wired bell/siren to terminals marked BELL+/BELL.
06 If using any powered sensors, connect them to AUX+/AUX-
terminals.
07 Connect a relay or other low power 12V device to the PGM output.
08 Connect a lead acid, 12 V battery to terminals marked BAT+/BAT.
Failing to observe correct polarity while connecting battery will
result in a shorted fuse!
09 If applicable, connect a supported USB device to the USB port.
10 If applicable, connect a supported device to the serial port.
11 Restore power to your Zipabox. When the top button on the
Zipabox turns solid green, your module is ready for confi guration
and use.
12 Login to my.zipato.com and click on “Total devices”, locate
Security module in the drop-down list.
13 Unhide all zones you wish to use (zones are hidden by default). On
the confi guration page for each zone, select wiring type.
14 After saving changes, press “Synchronize” button to transfer
them to your Zipabox.
INTRODUCTION
COMPATIBILITY
This Expansion Module is designed to work only with Zipabox.
HANDLING
Do not drop, knock or shake the module. Rough handling can break
internal circuit boards and connectors.
ENVIRONMENT
Do not expose the module to excessive heat or cold, as it can damage
or shorten the life of electronic circuit boards.
If possible, dispose this module at a recycling center.
Do not dispose of this module with the household waste.
1.0 FEATURES
6 wired zones (expandable to 24 using additional Security Modules)
1 optically isolated 12V input
1 supervised wired bell/siren output
1 programmable output
1 supervised 12V auxiliary power supply for powered wired
sensors
1 USB port
1 serial/UART port, user selectable between RS-232 mode and
half-duplex RS-485 mode
1 lead acid battery charger
ZIPABOX SECURITY
EXPANSION MODULE
QUICK INSTALLATION GUIDE
v1.0
Bottom left
angle view
Top right angle
view
Left side
view
1
RS-232-RX
4
RS-485-B
5
COM
54321
2
RS-232-TX
3
RS-485-A