® ZIP HydroTap G4 Celsius User Guide • Tap Operation..................(Pages 3-5) • LCD Screen & Menu .......(Pages 6-19) • Maintenance.................... (Pages 20-23) • Contact & Details............ (Page 24) • Date of Installation............./........./......... ARC CUBE Affix Model Number Label Here 802698 802698 - G4 User Guide - 09.16 - v2.
NOTES Page 2 of 24 802698 - G4 User Guide - 09.16 - v2.
Tap operation - Chilled Sparkling Turning the rotary control allows the dispensing of either Chilled Sparkling or Chilled water.
Tap operation - Boiling water To dispense Boiling water: with the safety ON. Tapping the illuminated RED safety button twice, with one finger, will cause the safety red light to flash for a few seconds. While flashing, turn the rotary control (as shown) to dispense boiling water. (See section G for safety settings) Rotate for Boiling water Safety To dispense Boiling water: with the safety OFF. When the RED safety light is OFF, turn the rotary control (as shown) to dispense boiling water.
Filter Warning and Reset Temperature Warning Light: The warning light will flash slowly for 1 sec On and 3 secs OFF whenever the water is not at the temperature set point. The tap may be operated, but the water may not be at the desired temperature . The slow flashing light will turn off once the water reaches the set point. The set point temperature is user adjustable (See section G). Filter Warning Light: As a reminder that the filter requires changing, the warning light will flash quickly every 10 secs.
3LCD Screen The Zip HydroTap G4 Celsius introduces a ‘TOUCH’ screen for easy setup and operation adjustment. Safety lock Icon Sleep Mode Icon Energy Mode Icon BHA window Set boiling water temperature Filter usage **Status window CHA window Set chilled water temp.
3LCD Main Menu Language Screen Menu Sub Menu • English Installation Service Security A • German • Product Info Information Sub Menu Options Section • System Faults • Event Log • Product serial no.
A LCD Screen operation - Section A Set Language 1. 2. 3. 4. Press [MENU] for main menu. Press [Language] button. Select the preferred language Press [<=] button for the previous menu LCD Screen operation - Section B B System Information In this section, you can find your product serial number , check system fault messages or view the event logs of your product. 1. Press the [MENU] button for main menu. 2. Press the [Info] button to view the product serial number and other key information 1.
C LCD Screen operation - Section C Install Once your Zip HydroTap G4 unit has been installed, Go to Install menu to configure the system settings for your product. Sub menu: 1. Filter Flush 2. Filter Reset 3. Boiling Calibration 4. Booster 5. Lux Sensor Calibration CHA Screen Follow 1,2 & 5.above CSHA Screen Follow 1,2 & 5.above Follow CO2 purge below CO2 Purge (CSHA Model) When fitting a new gas bottle, it is important to purge the gas lines. 1. Press the [MENU] button for main 2. 3. 4. 5. 6. 7. 8.
LCD Screen operation - Section C 1 - Filter Flush (All) Have a 10L bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the Filter Flush Mode is in operation. Open the filter access door on the front of the HydroTap and the filter cartridge will be exposed. Located to the rear RHS of the cartridge is a flush line, approx 600mm long and the flush line stop cock. Place the valve end of the flush line into the 10L bucket or container (not supplied). 1.
LCD Screen operation - Section C 2 - Filter Reset (All) After replacing the filter, the counters should be reset 1. Press the [MENU] button for main menu. 2. Press the [Install] button. 3. Press the [Filter Reset] button. 4. To set the filter life or edit filter usage, refer to section G- Filter. 3 - Boiling Calibration (Boiling models) Caution: In general, boiling water units may vent steam from the tap spout. Take care to avoid personal injury whenever this occurs.
5 - Lux (light level) Sensor Calibration (All) 1. Press [MENU] button for main menu. 2. Press [Install] button. 3. Press [Lux Sensor Calibration] button. 4. The lights on the Tap head will flash to confirm calibration. 5. Check for correct tap operation by selecting ‘Lux Sensor-> OFF’. When the room is darkened (below the calibrated light level), the tap lights will turn OFF after 24 seconds.
LCD Screen operation - Section E To change a password 1. Press the [MENU] button for main menu. 2. Press the [Security] button. 3. Press [Change Password} 4. Enter your old 4 digit password 5. Then enter your new 4 digit password. You will need to enter your password to access the settings screen. If you have forgotten the password, please disconnect the power and restart your HydroTap unit.
3. LCD Screen operation - Section G tions Set Date / Time G4 HydroTap Set Date/Time Screen 1. Press the [MENU] button for main menu. 2. Press the [Setting] button. 3. Press the [Date/Time] button. 4. Select either 12 hour or 24 hour mode. The selected mode will be displayed in a dark grey colour with a tick box on the right. 5. Press [NEXT] to set the time and date 1. Select individually the hour, minutes and day and adjust using the up and down arrows. 2.
3. LCD Screen operation - Section G Filter Zip HydroTap G4 allows the user to adjust filter life and edit filter usage. Note: The filter life may be set as a function of Litres used, or in months from the filter change. When the first of these functions is reached (i.e. Litres or months expired), the filter warning light will be illuminated on the tap. Either of these functions may be disabled (See below). To edit the filter life: 1. Press the [MENU] button for main menu. 2. Press the [Setting] button. 3.
LCD Screen operation - Section G Energy Modes (Boiling models) This mode allows the HydroTap to Go into Energy Saving mode. There are two options available: ‘Sleep’ mode and ‘ON/OFF’ mode. In SLEEP MODE the unit will Go to “Sleep” after a 2hr period of inactivity. The Boiling water will gradually drop to either 68°C or room temp, as shown in the table below and the Chilled water will be ON or OFF. When the period of inactivity passes, the home screen status window will show “Sleep Mode”.
LCD Screen operation - Section G In ON / OFF Mode the user may turn the unit ON or OFF at specific times for individual days or alternatively by weekly and/or weekend settings. To activate ON/OFF mode: 1. Press the [MENU] button for main 2. 3. 4. 5. 6. 7. menu. Press the [Setting] button. If required, Enter your 4 digit password Press the [Energy Modes] button. Select ‘Individual set’ if you wish to allocate a specific time for each day.
LCD Screen operation - Section G Safety (Boiling models) Boiling Only Models To set the safety using the touch screen: 1. Press the [MENU] button for 2. 3. 4. 5. main menu. Press the [Setting] button. If required, Enter your 4 digit password Press the [Safety] button. Press button B to Enable / Disable, the safety lock feature on the tap. B NOTE: When Disabled, boiling water may be dispensed from the Hydrotap by rotating the control anticlockwise.
Gas bottle change 1. Turn the CO2 bottle regulator OFF (Anti-clockwise). The knob will screw 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. up and away from the bottle. Dispense sparkling water for 30 seconds, until the water flow is free of gas. Remove the bottle from the cupboard and disconnect the regulator. If the braided hose is removed from the regulator, be careful not to loose the small plastic sealing olive, located inside the end of the hose.
Filter Maintenance The Zip HydroTap notifies when a filter replacement is due. If you notice one of the following, you will need to change the filter: • The Change Filter light will flash until reset. (See Section C) • The filter percentage will change to 0% on the screen. NOTE: Depending on local water quality conditions and usage, the filter may require changing anywhere from 500 Litres to 10000 Litres. You may also need to replace the filter if you notice unpleasant odours or tastes.
Filter Maintenance Warning: If the Zip HydroTap is switched off for a long period of time (e.g. More than a weekend), run water through the chilled water outlet for at least 5 minutes before consumption. Air Inlet Filter The Zip HydroTap air filter is conveniently located on the outside of the condenser. The filter screen is a sliding fit in the plastic housing on the side of the under sink unit. The screen may be removed for cleaning, by sliding it forward.
Home Menu Icons Safety switch is LOCKED. The HydroTap will not dispense any Boiling water. See page 18 for safety switch operation Safety switch is UNLOCKED. Boiling water may be dispensed. See page 4 for tap operation details Sleep mode is active. There are 7 sleep mode options which display this icon on the home screen. See page 16 for details. Heater is in OFF mode. When this icon is displayed, no power is being supplied to the heating element. See pages 16 and 17 for Energy Mode options.
NOTES 802698 - G4 User Guide - 09.16 - v2.
Contact Details Head Office Zip Heaters (Aust) Pty. Ltd. ABN: 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia Website: www.zipindustries.com Facsimile: (02) 9796 3858 Telephone: (02) 9796 3100 Sales & Service. Free Call: 1 800 63 86 33 Customer Care. Free Call: 1 800 42 43 44 As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice.