Installation instructions & user manual Zip Miniboil Models: Boiling/Ambient, Boiling Only AFFIX PRODUCT LABEL HERE 805757 805757 v1.05 06.
Checklist Before Installation: A. Read the instructions. B. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied. C. The pressure limiting valve must be fitted as part of the kit. D. Check the water quality to determine if extra filtration will be required. E. Check the appliance rating plate and ensure correct power is available for the appliance. F.
Contents Contents WARNINGS AND PRECAUTIONS......................................4 Technical specification................................................... 5 Installation requirements............................................... 5 Special tools required..................................................... 6 Installation..................................................................... 6 Step A - Installing the tap................................................... 6 Step B - Installing the filter.....
WARNINGS AND PRECAUTIONS ! The power point must be located within reach of its cable. The appliance must be positioned so that the plug is accessible. For continued safety of this appliance it must be installed, operated and maintained in accordance with the manufacturer’s instructions. This appliance may deliver water at high temperature. Refer to the Plumbing Code of Australia (PCA), local requirements and installation instructions to determine if additional delivery temperature control is required.
WARNINGS AND PRECAUTIONS Installation environment considerations This unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature. This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water jet. Technical specification MODEL Miniboil BA, Miniboil BO Capacity 1.8 Litres Power rating 1500 Watts Width x Depth x Height (mm) 212 x 269 x 338 Weight (dry) 6.5 kg Weight (full) 8.
Special tools required In addition to normal tools, the following will be required: • 35mm diameter sheet metal hole punch for sink tops (not supplied) • 35mm diameter hole saw for timber bench tops (not supplied) • Nut runner tube spanner (supplied) for fixing tap assembly. Installation Step A - Installing the tap ! Fixing nut Spider clamp Black spacer Smear silicon on underside of flat surface Tap all-thread rod black plastic spacer benchtop s/s washer 1.
Installation Step B - Installing the filter Miniboil is supplied with an external filter (see diagram below). It is important the filter be securely fixed adjacent to the under sink unit in such a manner as to allow for easy access to the filter, for service and regular replacement. The ¼” LDPE tube supplied must be carefully measured and cut to allow for the connection of the filter, double check valve and JG fittings. Step C - Installing the Command Centre Fig 1.
Installation Fig 3. Cartridge replacement Filter insertion and replacement (Fig 3) Align the tabs of the cartridge with the filter housing and insert it up into the socket. Turn the cartridge a quarter turn to the right until it locks into position. Reverse this procedure for removal. INSERT 1 ROTATE 2 PULL DOWN Cartridge Removal 1 2 ROTATE Cartridge Insertion Fig 4.Boiling/Ambient models: Connection viewed from the top Fig 5. Boiling Only model: Connection viewed from the top Fig 6.
Operation Boiling Only model: Press or pull either red lever, and cover the Safety button at the same time. Boiling water (BA model): Press or pull the red lever, and cover the Safety button at the same time. Cold (ambient) water (BA model): Press or pull the blue lever. Boiling water will be dispensed. Boiling water will be dispensed. Cold water will be dispensed. Note: If the appliance has not been used for several days, allow the tap to run ambient water for about one minute.
Operation Sleep mode (for BA model only) Activate / deactivate sleep mode (BA model): Press the blue lever and the Safety button and hold them for about five seconds. The unit can be set to Sleep mode to save energy. If Sleep mode is enabled, the unit will switch to Sleep if it has not been used for two hours. The water temperature will be maintained at 64 °C. Operation of the tap during this time will wake the system from sleep and the water will start heating up again.
Troubleshooting Symptom Possible Cause Solution No LED display, no tap head lights or, no water when tap is operated. No power. Plug is not located in power socket. Tap loom is not connected to the unit. Possible internal fault. Check power supply. Ensure power plug is correctly fitted and switch is turned ON. Check loom connection. Contact local Zip Service Provider. No water flow. Water supply isolated. Water supply not connected. Power supply not connected. Tap loom is not connected to the unit.
Zip Water (Aust) Pty Ltd ABN 46 000 578 727 67-77 Allingham St, Condell Park NSW 2200 Postal: Locked Bag 80, Bankstown 1885 Australia T: +(61 2) 9796 3100 zipwater.com | 1800 ZIP TAP (1800 947 827) The terms “Zip” and “HydroTap” are registered trade marks of Zip Water (Aust) Pty Ltd. Zip products described in this publication are manufactured under one or more patents and further patent applications are pending.