Installation and Operating Instructions Zip Hydroboil ® Instant boiling water HS010 HS110 HS015 HS115 HS025 HS125 HS040 HS140 Hydroboil 10 Litre White Hydroboil 10 Litre Stainless Steel Hydroboil 15 Litre White Hydroboil 15 Litre Stainless Steel Hydroboil 25 Litre White Hydroboil 25 Litre Stainless Steel Hydroboil 40 Litre White Hydroboil 40 Litre Stainless Steel 10552 10551 11552 11551 12552 12551 04552 Zip Hydroboil - Installation & Operating Instructions - 81447 - April 2013 v1.
Description Wall mounted Over-sink appliance for instant boiling water. Features: • Designed to operate within 1°C of boiling point.# • Temperature controls automatically cut off the power in the event of temperature control failure, boil dry cutout or a blocked vent pipe. • Incorporating a pull down tap for precision filling of cups, it also locks ‘ON’ for filling pots. • Separates the cold water supply from the boiling chamber and the internal condensing system retains steam within the heater.
Contents Product Specifications / Accessories............................................................................................................................4 Read These Warnings First...................................................................................................................................... 4 - 5 Installation Requirements..............................................................................................................................................
Product Specifications Delivery Recovery Capacity Cups @ any Cups per Litres one time hour Rating kW @ 230V Width mm Depth mm Height mm Weight Empty Kg Weight Filled Kg 3.0 390 244 600 15.0 29.5 Model Finish HS010 White HS110 s/steel 10 60 180 3.0 390 244 600 15.0 29.5 HS015 White 15 90 180 3.0 390 299 600 16.0 34.5 HS115 s/steel 15 90 180 3.0 390 299 600 16.0 34.5 HS025 White 25 150 180 3.0 390 299 780 19.0 47.0 HS125 s/steel 25 150 180 3.
Read These Warnings First Cont. Safety This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Installation Requirements Cont. Minimum Clearance in mm b. c. Size 10 Ltr 15 Ltr 25 Ltr 40 Ltr Kw 3.0 kW 3.0 kW 3.0 kW 6.0 kW Amps 13 A 13 A 13 A 30 A d. e. f. g. Electrical supply. A standard 13 amp double pole fused spur on the wall within 1500mm of the heater. Isolation switches must have a contact separation of at least 3mm in all poles. The circuit should be protected by a suitably rated RCD. HS140/HS040 (40ltr) should be provided with their own dedicated 30A supply.
Installation Procedures Continued Approximate Weights When Filled 10 Litre models 29.5 kg 15 Litre models 34.5 kg 25 Litre models 47.0 kg 40 Litre models 71.0 kg Step 3 – Connecting Fig. a 250mm a) Wiring 45mm Plumbing For exposed plumbing connection, connect the cold water inlet pipe from the base of the heater directly to the 15mm or 1/2 inch BSP compression fittings.
Installation Procedures Continued Flow Restrictor Note: If the heater is used for filling cups, then insert the flow restrictor into the outlet pipe before securing tap assembly as above.
Template Dimensions 374mm (10L, 15L, 25L) 499mm (40L) 295mm (15L, 25L) 420mm (40L) 39.5mm 39.
Single Element Up To 3Kw with One Pole T.O.L Thermal Over Load Thermostat Controlled HS140 & HS040 With Contactor T.O.L: Thermal Over Load Thermostat Controlled Problem Solving Symptom Fails to dispense water. Water not boiling. Possible Cause Solution Water isolating valve turned off. Check water supply valve. Blocked filter, meter tube, strainer, jammed ball valve assembly or airlock in transfer tube. Contact a Zip authorised agent. No power. Check power supply.
Spare Parts Key Part No Description Key Part No 1 Cistern lid clamp kit 15 SP90502 2 SP90120 Cistern lid gasket kit 17 SP90505 Tap nut kit 3 SP90490 Gasket kit 18 SP90506 Tap extension 4 SP90083 Float valve kit, with float 19 SP90486 Element kit 3.0kW 230V 5 SP90069 Jumper valve kit, with seals 20 SP90491 Cleaning hole cover kit 6 SP90102 Cistern float 21 SP90492 Drain cap & seal kit SP6245 Description Tap assembly complete 7 SP90494 Transfer tube kit - 2.
End of life disposal The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste. Within each of the European Union member countries, provisions have been made for the collection and recycling of unwanted electrical and electronic equipment. In order to preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service for advice on 0845 6 005 005.