Technical data
Electronic under-sink instantaneous water heaters 11 – 13 kW
Technical Data
69
Closed-outlet installation Power supply with load shedding circuitOpen-outlet installation
Model CDX-U BASITRONIC
®
CEX-U ELECTRONIC MPS
®
CFX-U FUNKTRONIC MPS
®
Product code 26113 26213 26313
Use
Nominal capacity litres 0.3 0.3 0.3
For single outlet / For two outlets • / • • / • • / •
Application handwash basin /
kitchen sink
• / • • / • • / •
Installation type (water connections at top) undersink undersink undersink
Electrical data
Type closed-outlet • • •
Maximum static pressure MPa (bar) 1 (10) 1 (10) 1 (10)
Water connections (thread connection) G
3
/
8
“ G
3
/
8
“ G
3
/
8
“
Temperature adjustment °C
Factory setting: 50, (installer
adjustable between 30 and 60)
User: 20 to 60 User: 20 to 60
Hot water flow rate at ∆t = 33 K
1) 2)
l/min 4.8 4.8
3)
5.8
2) 3)
4.8
2) 3)
5.8
2) 3)
Switch-on – maximum flow rate
4)
l/min 2 – 5 2 – 5 2 – 5
Nominal power rating
5)
kW 11.0 11.0 13.5 11.0 13.5
Supply voltage V 3 / PE ~ 400 3 / PE ~ 400 3 / PE ~ 400 3 / PE ~ 400 3 / PE ~ 400
Nominal current A 3 × 16 3 × 16 3 × 20 3 × 16 3 × 20
Required cable size mm
2
1.5 1.5 2.5 1.5 2.5
6)
VDE approved, CE endorsed / Protection class • / IP 24 • / IP 24 • / IP 24
Equipment
Control electronical electronical electronical
IES
®
Bare wire heating system / Ω cm
7)
• / 1000 • / 1000 • / 1000
Power cable • • •
Multiple Power System MPS
®
/ Twin Temperature Control TTC
®
• / • • / •
Temperature display LCD Remote control with LCD
Programme buttons / Operating status indication 2 / • 2 / •
Solar-compatible (Inlet temperature < 70 °C) • •
Remote control module as accessory included in the package
Dimensions and weight
Dimensions (Height × Width × Depth) cm 29.4 × 18 × 11 29.4 × 18 × 11 29.4 × 18 × 11
Approx. weight (filled with water) kg 2.7 2.7 2.7
• = included resp. yes 1) Temperature increase e.g. from 12 °C to 45 °C 2) Mixed water 3) Depending on the selected connection power rating. 4) Flow limited in order to obtain optimal temperature increase
5) Regulations vary according to the regional power supply authority. Must only be connected by a qualified electrician. 6 ) Use the power supply cable supplied 7) Permissible minimum electrical resistance of the
water at 15 °C