Technical data

66
Mini instant water heaters 3 7 kW
Technical Data
66
Model MH 3 MH 4 MH 6 MH 7 MDH 3 MDH 4 MDH 6 MDH 7
Product code 14003 14004 14006 14007 12003 12004 12006 12007
Complete systems with single-lever mixer tap M 3 / ENM
with two-handle mixer tap M 3 / SNM M 4 / SNM
with two-handle mixer tap for oversink wall-mounting M 3 / SMB M 4 / SMB M 7 / SMB
with shower set M 4 / BGS M 6 / BGS M 7 / BGS
Use
Nominal capacity litres 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
For single outlet
Application handwash basin / kitchen sink • / – • / – • / • • / • • / – • / – • / • • / •
Installation type undersink unit
oversink unit MH 3-O MH 4-O MH 6-O MH 7-O
Electrical data
Type open-outlet / closed-outlet • / – • / – • / – • / – – / • – / • – / • – / •
Maximum static pressure MPa (bar) open-outlet open-outlet 1 (10) 1 (10) 1 (10) 1 (10)
Water connections (thread connection) G
3
/
8
G
3
/
8
G
3
/
8
G
3
/
8
G
3
/
8
G
3
/
8
G
3
/
8
G
3
/
8
Hot water flow rate at ∆t = 25 K
1)
l/min 2.0 2.5 3.3 3.7 2.0 2.5 3.3 3.7
Switch-on – maximum flow rate
2)
l/min 1.6 – 2.0 1.8 – 2.5 2.1 – 3.3 2.4 – 3.7 1.6 – 2.0 1.8 – 2.5 2.1 – 3.3 2.4 – 3.7
Nominal power rating
3)
kW 3.5 4.4 5.7 6.5 3.5 4.4 5.7 6.5
Supply voltage V 1 / N / PE ~ 230
2/PE ~ 400
1 / N / PE ~ 230
2/PE ~ 400
Nominal current A 15 19 25 2 × 16 15 19 25 2 × 16
Required cable size
3)
mm
2
1.5 2.5 2.5 2.5 1.5 2.5 2.5 2.5
VDE approved, CE endorsed / Protection class • / IP 24
4)
• / IP 24
4)
• / IP 24
4)
• / IP 24
4)
• / IP 24
4)
• / IP 24
4)
• / IP 24
4)
• / IP 24
4)
Features
Control hydraulical
IES
®
Bare wire heating system / Ω cm
5)
• / 800 • / 800 • / 800 • / 800 • / 800 • / 800 • / 800 • / 800
Replaceable heating cartridge
Power cable with plug / for permanent connection • / – – / • – / • – / • • / – – / • – / • – / •
T-piece with pressure hose
Special jet regulator
Dimensions and weight
Dimensions (Height × Width × Depth) cm 13 × 18.5 × 8 13 × 18.5 × 8
Approx. weight (filled with water) kg 1.2 1.2 1.2 1.2 1.3 1.3 1.3 1.3
• = included resp. yes 1) Temperature increase e.g. from 15 °C to 40 °C 2) Flow limited in order to obtain optimal temperature increase 3) Regulations vary according to the regional power supply authority.
Must only be connected by a qualified electrician. 4) As oversink unit: Protection class IP 25 5) Permissible minimum electrical resistance of the water at 15 °C
Closed-outlet installation (MDH and MDX)
The mini instantaneous
water heaters MDH and
MDX are approved for
unvented (closed outlet)
installation.
The connection set supplied
with the unit (T-piece and
flexible hose) simplifies
retrofitting to existing
closed-outlet taps.
Open-outlet installation (MH)
Mini instant water heaters with open
outlet design can be mounted very
quickly and easily in an open outlet
installation.
They are designed to supply a single
tap outlet. To prevent pressurisation
of the unit, a special open-outlet tap
must be used.