Installation Guide
Page 18 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01
OPEN Position
CLOSED Position
ON
OFF
Stop cock
operation
Commissioning
NOTE: For any subsequent fi lter changes or any operational procedures, please refer to the HydroTap user
guide, located inside the fi lter housing access door.
1.
Press [Start] [Stop] buttons to start and stop the filter
flush.
2.
Turn the flush line stop cock ON (See diagram).
3.
Press [Start] and allow at least 10 litres of water to flush
through the filter.
4.
The product details will be displayed in the screen.
5.
Once the filter flush is finished, Turn the stop cock OFF
then press [Stop] to end filter flush mode.
6.
Press [Next] for the Boiling Calibration screen.
Have a 10L bucket or similar container (not supplied) at the ready to hold a quantity of water that will be
ejected while the Filter Flush Mode is in operation. Open the filter access door on the front of the HydroTap
and the filter cartridge will be exposed. Located to the rear RHS of the cartridge is a flush line, approx 600mm
long and the flush line stop cock. Place the valve end of the flush line into the 10L bucket or container.
5.3 - Filter Flush