ZIP HydroTap G4 ® User Guide Affix model number label here 802258UK 802258UK G4 Boiling (& ambient) residential, user guide - August 2015 - V2.
3. Table of contents • Boiling and boiling ambient tap models. Page 2 • Tap safety.................................................. Page 3 • Tap operation............................................ Pages 4 to 7 • Safety sensor calibration......................... Page 8 • Tap lights................................................... Page 8 to 9 • LCD screen & menu.................................. Pages 10 to 22 • Filter maintenance.................................... Pages 22 to 23 • Home menu icons...
. Tap safety The safety lock feature is provided to prevent boiling water flowing if the red BOILING control is inadvertently activated. This function can be activated and deactivated from either the tap or from the touch screen display (located on the Command-CentreTM). To activate the safety lock (from the tap) Classic and Elite boiling ambient models only. (Ensure ‘Allow safety settings change’ is selected, see page 21).
3. Tap operation To dispense boiling water (with the safety lock off) Classic Depressing the red BOILING lever allows the dispensing of boiling water. Pulling forward the red BOILING lever allows the tap to operate in a “no-touch” mode. Water will flow from between 5 and 15 seconds (this is user adjustable, see page 22). To reset, return the lever to the “off” position and repeat the step. (The lever has to be manually returned to the “off” position).
3. Tap operation To dispense ambient water Classic Depressing the blue AMBIENT lever allows the dispensing of AMBIENT water. Pulling forward the blue AMBIENT lever allows the tap to operate in a “notouch” mode. Water will flow from between 5 and 15 seconds (this is user adjustable, see page 22). To reset, return the lever to the “off” position and repeat the step. The lever has to be manually returned to the “off” position. Elite Touching the blue AMBIENT button allows the dispensing of AMBIENT water.
3. Tap operation Arc / Cube On powerup, wait 30secs. for the unit to calibrate before selecting either the red illuminated BOILING with safety, or blue illuminated AMBIENT water mode, by touching the select button. The Arc / Cube control may be rotated in a forward or reverse Rotary control direction to Select button dispense boiling or ambient water. The rotary control Safety button is spring loaded in the forward direction and when released, will return to the OFF position.
3. Tap operation Classic mixer tap Lifting the lever up will increase the flow rate and lowering the lever will decrease the flow rate. Lower the lever all the way down to close the tap. When the lever is moved in the direction of the blue dot, the temperature is decreased and when moved in the direction of the red dot, the temperature is increased. The final temperature will be dependant on the temperature of the incoming cold water.
Safety sensor calibration Light intensity varies from site to site, therefore it is recommended that a recalibration be performed at the time of the installation. All direct sunlight must be shaded from the HydroTap®G4, during the calibration. This can be achieved by closing any nearby curtains, blinds, etc. Procedure • • • • • • Shield the HydroTap®G4 from any direct sunlight. With the Command-CentreTM in normal operating mode turn the power off. Pull both tap levers to the forward position.
Tap lights Warning light all models Flashing warning light When the indicator light flashes fast and continuous, a system fault has occurred. Check for details on the faults screen. If unable to rectify, call a qualified service agent. Red warning Filter light light Filter light Classic and Elite Filter light off This indicates the filter is operating within its normal specified lifespan.
3LCD Screen Zip HydroTap®G4 features a ‘TOUCH’ screen for easy setup and operation adjustment. (See page 24 for home menu icons). **Status window Safety lock icon Set boiling water temp.
3LCD Main menu Language Screen menu Sub menu Sub menu options A English / Deutsch • Product info.
LCD Screen operation - Section A A. Set language • • • • Press the [MENU] button for main menu. Press the [Language] button. Select the country. Press [<=] button for the previous menu. LCD Screen operation - Section B B. System information In this section, you can find your product serial number, check system fault messages or view the filter logs of your product. • • • • • • • • • • • • Page 12 of 24 Press the [MENU] button for main menu. Press the [Info] button.
LCD Screen operation - Section C C. Install Once your Zip HydroTap®G4 unit has been installed, Go to the install menu to configure the system settings for your product. Sub menu 1. - Filter flush. 2. - Filter reset. 3. - Boiling calibration. 4. - Booster. 5. - Lux sensor calibration. 1. Filter flush Have a bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation.
LCD screen operation - section C 2. Filter reset After replacing the filter, the counters should be reset. • • • • • • • Press the [MENU] button for main menu. Press the [Install] button. Press the [Filter Reset] button. Press the [Reset Internal Filter] / [Reset External Filter] button. If you need to flush the filter follow the filter flush guide, see page 13. To cancel the filter reset program press [HOME] or [<=]. To set the filter life or edit filter usage, see page 18. 3.
LCD Screen operation - Section C 5. Lux sensor calibration • • • • Press the [MENU] button for main menu. Press the [Install] button. Press the [Lux Sensor Calibration] button. The lights on the tap head will flash to confirm calibration. LCD Screen operation - Section D D. Service Caution must be observed when changing any settings within the service menu as any changes may affect the normal operation of the unit. This can only be done by a Zip technician.
3. LCD Screen operation - Section E E. Security The Zip HydroTap®G4 allows the appliance coordinator to set up a password to protect against users changing the preferred system settings. To set a password • • • • • Press the [MENU] button for main menu. Press the [Security] button. Press [Enable Password]. Enter a 4 digit password. Press [Enter]. To change a password • • • • • Press the [MENU] button for main menu. Press the [Security] button. Press [Change Password].
3. LCD Screen operation - Section G g Instructions G. Settings • • • • Press the [MENU] button for main menu. Press the [Settings] button. Enter your 4-digit password and press [Enter]. Once the password has been set you will need to enter the password to access the settings screen. If you have forgotten the password see page 16, LCD screen operation - section E security.
3. LCD Screen operation - Section G Filter Zip HydroTap®G4 allows the user to adjust filter life and edit filter usage. Note The filter life may be set as a function of litres used, or in months from the filter change. When the first of these functions is reached (i.e. litres or months expired), the filter warning light will be illuminated on the tap. Either of these functions may be disabled. To edit the filter life Press the [MENU] button for main menu. • Press the [Settings] button.
3. LCD Screen operation - Section G Energy modes This mode allows the HydroTap®G4 to go into energy saving mode. There are two options available: sleep mode and on/off mode. In sleep mode the unit will go to “Sleep” after a 2hr period of inactivity. The boiling water will gradually drop to either 68°C or room temp, as shown in the table below and the AMBIENT water will be ON or OFF. To activate sleep modes • Press the [MENU] button for main menu. Press the [Settings] button.
LCD Screen operation - Section G Note Any attempt, during off mode, to dispense water, will bring the unit out of sleep mode. The unit will return to sleep mode after 2 hours of non use. Please allow sufficient time for the water to reach the set temperature after disabling the sleep mode. On/Off mode allows the user to turn the On/Off mode menu unit on or off at a specific time or day. To activate On/Off mode • • • • • Individual set screen Press the [MENU] button for main menu.
LCD Screen operation - Section G Safety Boiling only models To set the safety lock using the touch screen • • • • • Press the [MENU] button for main menu. Press the [Setting] button. Enter your 4-digit password and press [Enter]. Press the [Safety] button. Press button B to enable / disable the safety lock on the tap. B C Boiling ambient models To allow the safety setting to be changed using the touch screen (Classic and Elite) • • • • • Press the [MENU] button for main menu.
LCD Screen operation - Section G Dispense Times The ability to change the maximum dispensing time for both the hot and cold water has been introduced. The default settings for the maximum dispensing times is 15 seconds. The operator may change both the hot and cold dispensing times from 5 to 15 seconds, in increments of 1 second. To edit the dispensing times. • • • • • Press the [MENU] button for main menu. Press the [Settings] button. Enter your 4-digit password and press [Enter].
Filter maintenance • • • • • • • • • • Caution. A small amount of water will drip as the cartridge is removed. Do not tilt the cartridge as water may spill from it if tilted. Unpack replacement cartridge and remove sanitary cap, write today’s date where shown on the label. Avoid touching the filter o-rings and filter opening as this may cause bacterial contamination of the cartridge.
Home menu icon Home menu icons Safety switch is enabled. The HydroTap®G4 will not dispense any Boiling water. See page 3 for safety lock operation. Safety switch is disabled. Boiling water may be dispensed. See page 4 for tap operation details. Sleep mode is active. There are 7 sleep mode options which display this icon on the home screen. See page 20 for details. Heater is in off mode. When this icon is displayed, no power is being supplied to the heating element. See page 19 for Energy Mode options.