802259UK - Residential Boiling (& ambient) - Quick start guide - August 2015 - V2.01
Booster system
Note 1 Water connection.
Blue cap - water in.
Red cap - water out.
The braided hoses cannot be
lengthened.
Note 2 Position the booster
according to the flexible hose
and cable lengths supplied.
Keep the booster as close as
possible to the Command-
Centre
TM
inlet / outlet fittings.
Note 3 Ensure the booster
heater is mounted in an
upright position (as shown)
with a horizontal base.
Step 3 -
Install the booster (if required).
Step 4-
Installing the Command-Centre
TM
.
Note The braided hose and connection tubes cannot be lengthened.
Command-Centre
TM
installation
Tilt Forward Lift UP
Release
Remove the mounting chassis for wall mounting.
RED
CLEAR
BLUE
BRAIDED
POWER
CABLE
USB
MAINS
IN
MIXER
OUT
MIXER
IN
BOILING
OUT
BYPASS
IN
VENT
BYPASS
OUT
AMBIENT
OUT
280mm
Note
Ambient
mains water braided
hose length is
750mm.
Electrical power
cable length is
1800mm.
Position the
Command-Centre
TM
according to the
hose and cable
lengths supplied.
Clearance
Envelope
535mm
50mm
50mm
mount base
horizontally
Note All silicon tubes / plastic pipes must
be cut to size. They must have a constant
fall back to the Command-Centre
TM
.
Example
HydroTap
®
G4 Classic boiling ambient model
Arc / Cube
Elite Classic
Boiling Water
03:01 PM, TUE 12, Feb 2013
Boiling
Zip
To start
press
Calibrate
button
Calibrate
Steam Vent
97.5
53.0
EL
Commissioning
OPEN Position
CLOSED Position
ON
OFF
Stop cock
If a BOOSTER is installed,
enable in < INSTALL > Menu
03:01 PM, TUE 12, Feb 2013
Boiling
Zip
HOME
Prepare filter flush as per instructions
and press START
03:01 PM, TUE 12, Feb 2013
Boiling
Zip
START
STOP
NEXT
To calibrate, touch START button
NEXT
03:01 PM, TUE 12, Feb 2013
Boiling
Zip
START
Empty / Filling
Pulses/L (360 - 440)
Have a bucket or similar container
(not supplied) at the ready to hold a
quantity of water that will be ejected
while the filter flush mode is in
operation. Open the filter access door
on the front of the Command-Centre
TM
and the filter cartridge will be exposed.
Located to the rear right hand side
of the cartridge is a flush line, approx
600mm long, and the flush line stop
cock. Place the free end of the flush
line into the bucket or container (not
supplied).
Note
at first commissioning, the
system will select the filter flush screen
automatically.
Turn the flush stop cock on.
Press [START] button to start filter flush.
Allow at least 10 litres of water to flush
through the filter.
Once the filter flush is finished, turn the
flush stop cock off then press [STOP] to
end filter flush mode.
Press [NEXT] and the screen will display
the flow calibration screen.
Press the [START] button and the tank
will first empty then fill. Upon completion
the pulse count will be displayed. Check
this reading is within the limits.
Press [NEXT] for the boiling calibration
screen.
Press the [Calibrate] button and the
system will commence the boiling
calibration procedure. This will take
approximately 5-6 minutes.
Upon completion, a booster reminder
screen will appear and allow you to
return to the home screen by pressing
the [HOME] button.
Check the date and time settings, see
section G of the User guide.
To enable the booster (if fitted).
Press the [MENU] button for main menu.
Press the [Install] button.
Press the [Boost] button.
In the next screen select [YES] to
enable the booster.
Water must be run through the booster
for a minimum of 30 seconds, before the
heater is activated.
Dispense boiling water for 30 seconds
and check the booster outlet hose is
warm when the boiling water tank is
replenishing.
Hot water
connection
(outlet,3/8”
BSP)
Strainer
Cold water
connection
(inlet,3/8”
BSP)
Braided hoses
Hold the hexagon while tightening the
braided hose fittings.
Step 5-
Commissioning.
Commissioning
Initial commissioning screen
To set the language
Press the [Language] button for main menu.
Select [English] of [Deutsch].
Language selection screen
Zip Boiling
Note Connect the mains water braided hoses to
the Command-Centre
TM
before locating in place.