Installation Guide
802257 - HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2015 - v2.00 Page 27 of 36
Section 4
Undersink Unit installation
If an external filter is installed, select position B
B
Rotate 90°
only
1
2
3
4
Check the table below to determine which filter bypass position you need for your product.
Note:
Before you install a unit, determine whether a water softener or an external filter is required.
4.1
E
xternal Bypass Valve
The diverter bypass valve allows the user to choose to have the boiling feed water bypass the internal filter
and only be filtered by the external filtration. This diverter valve is located at the rear panel of the Zip HydroTap
undersink unit on the filter door side, see the image below.
4.2 Hose and tube fitting. (Do not overtighten)
•
Remove all caps from the top of the undersink unit
•
Install the mains water braided hoses to the undersink unit before locating the unit in place.
If no external fi lter is installed, select position A
A
Rotate 90°
only
1
2
3
4