Installation Guide
Page 16 of 40 801314 - Zip HydroTap BC, BCHA, AIO, Installation Instructions - Aug 2015 - V2.01
Cut a 35mm hole in the bench / sink top.
SINK TOP
1.10
35mm
Note: make sure the tap location will allow
the nozzle to drain into the sink.
Tap assembly exploded view and kitchen layout side view.
BRAIDED
HOSE x 3
Mixer Tap Installation
1.11
O-RING
LOWER
RUBBER
WASHER
WASHER
NUT
External Mains
Blue band
Mixer IN
Red band
Mixer Out
Note
:
The mixer tap requires a Zip Restricta! ow
valve, as supplied, to be " tted in the cold
water supply line, from the isolation valve tee
piece, to the mixer tap. (See Fig. 1.13)
Min 300mm
Red Band
Blue Band