Installation Guide
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 13 of 20
Section 3
CO
2
Cylinder
WARNING:
This cylinder mus be installed in an open plan area or in an enclosed room, with a volume no less than 20m
3
.
If more than 1 gas cylinder containing CO
2
is present within the same location, the recommended ventilated
area should be in proportion to the number of gas cylinders stored in that location.
A ventilated area is a non-enclosed area which could include the kitchen, living room etc.
See gas bottle and MSDS sheet for a complete list of warnings. (See: www.zipindustries.com)
3.1 Secure the cylinder mounting:
Secure the gas bottle supplied to a suitable wall, within 1 metre of the unit, in an upright position. This is done
by screwing the metal plate holding the Hook-and-loopstrap to a cupboard wall, 200mm above the floor or
base of the cupboard. Make sure the gas bottle can stand before securing to the wall.
Due to regulatory requirements the gas bottle must be stored securely and in an
upright position.
3.2 Connect the regulator:
Make sure the regulator knob is turned fully anti-clockwise to the end-stop before fitting. Fit the regulator
to the gas bottle. Be aware that some CO
2
may be discharged from the connection to the regulator as the
bottle and the regulator are be assembled together. Any CO
2
released will be cold. Continue to screw on the
regulator to stop this leakage.
3.3 Connect the gas hose:
Connect the braided gas hose to the threaded end to the regulator (Do not lose the small sealing olive).
NOTE:
Care must be taken when working with high pressure carbon dioxide, and in no cases should the
normal operating pressure of 2.7-3.0 bar (270-300kPa) be exceeded.
Connect the unit to the mains power supply.