Installation and Operation Guide
802253 - HydroTap BC, BCHA -AV, AIO, Installation Instructions - June 2015 - V2.01 Page 21 of 36
Installation Instructions
1.20
Typical All-In-One Vented assembly with Booster heater (See section 3)
Booster
COLD isolation valve
(Not supplied)
Restrictafl ow valve & Tee
(Supplied)
Restrictaflow valve
Note:
The All-In-One vented taps require a Zip Restrictafl ow valve and Tee piece, as supplied, to be fi tted in
the cold water supply line, from the isolation valve (Not supplied), to the mixer tap. (See diagrams)
Note: All
silicon tubes
must be cut to
size. They must
have a constant
fall back to the
unit.
Note:
- Mains hose
length is 750mm
- Plug and Cord
length is 1800mm
Position the under
sink unit close
to the outlet tap,
within reach of
the hose and cord
lengths supplied