Specifications Sheet
A. Location
Tap must be positioned so that it drains into a
suitable sink. Tap should be situated as closely
as possible to directly above the under-sink G4
Command-Centre. Maximum distance from the
base of the tap to the G4 Command-Centre is
one metre (may be extended if required).
G4 Command-Centre must have clearances as
shown on the drawings. Ventilation accessories
(supplied) must be installed as per instructions.
B. Plumbing
Must be installed in accordance with
AS/NZS3500 plumbing regulations. Designed
for direct connection to a potable (drinkable)
cold water supply with minimum pressure of 172
kPa. A 500 kPa pressure limiting valve and dual
check valve are fitted internally to comply with
AS/NZS3500. An isolating valve should be fixed
between the water supply and the under-bench
G4 Command-Centre.
C. Electrical
Installed with an externally mounted 2.2 kW
booster unit (supplied), this model must be
connected via two 10 amp GPO power points
to 240-230 volt AC power supply in accordance
with AS/NZS3000 wiring regulations.
Caution
In some hard water areas where mineral
scale accumulation can become a problem,
consideration should be given to the
maintenance required. All G4 Command-Centre
units come with an internal bypass to simplify
the connection of an added external filtration or
water softening system.
Warranty
Five year warranty.
Appliance warranty 36 months
plus additional 24 months tank
warranty. See website for details.
Accessories
91290 – Zip 0.2 micron replacement filter
Standard tap finish: bright chrome.
Brushed chrome or black also available.
Call Zip for details and a quotation.
Technical Assistance
Zip Heaters (Aust) Pty Ltd
67-77 Allingham Street
Condell Park NSW 2200
Free Call 1800 638 622
www.zipindustries.com
As Zip policy is one of continuous product
improvement, changes to specifications may
be made without prior notice. The terms ‘Zip’,
‘HydroTap’, ‘Power-Pulse’, ‘Free-Flow’ and
‘G4 Command-Centre’ are trade marks.
Note: Zip HydroTap All-In-One “vented”
models are designed to be connected to
only a cold incoming water supply. For
alternative models connected to both hot
cold incoming water supplies, to provide a
larger volume of hot water for dish washing,
refer to “mains” models.
50 min.
280
50 min.
Inlet Vent
ø
50 mm diameter hole
162 reach
135
186
Mains cold water
isolation valve
(not supplied)
Restrictaflow
Booster
Clearance
Envelope
Residential Specification Sheet | Z0775 June 2014
Order Code Zip Model Rating (kW) @ 230 V Cabinet Dimensions W x D x H (mm)
HT1791 Zip HydroTap G4 BCHA “Vented” 1.55 + 2.2 280 x 476 x 333
* This model is installed with an external 2.2 kW booster. The G4 Command-Centre and booster each require a 10 amp power point.
Zip HydroTap
®
G4 All-In-One BCHA “Vented”
Boiling | Chilled | Filtered | Instantly | Hot + Cold