Section 4
CO
2
Cylinder
WARNING:
This cylinder mus be installed in an open plan area or in an enclosed room, with a volume no less than 20m
3
.
If more than 1 gas cylinder containing CO
2
is present within the same location, the recommended ventilated
area should be in proportion to the number of gas cylinders stored in that location.
A ventilated area is a non-enclosed area which could include the kitchen, living room etc.
See gas bottle and MSDS sheet for a complete list of warnings. (See: www.zipindustries.com)
4.1 Secure the cylinder mounting:
Secure the gas bottle supplied to a suitable wall, within 1 metre of the unit, in an upright position. This is done
by screwing the metal plate holding the Hook-and-loop strap to a cupboard wall, 200mm above the floor or
base of the cupboard. Make sure the gas bottle can stand before securing to the wall.
Due to regulatory requirements the gas bottle must be stored securely and in an
upright position.
4.2 Connect the regulator:
Make sure the regulator knob is turned fully anti-
clockwise to the end-stop before fitting. Fit the regulator
to the gas bottle. Be aware that some CO
2
may be
discharged from the connection to the regulator as the
bottle and the regulator are be assembled together. Any
CO
2
released will be cold. Continue to screw on the
regulator to stop this leakage.
Note: The regulator comes pre-set fixed pressure at 300kPa.
4.3 Connect the gas hose:
Connect the braided gas hose to the top of the
undersink unit via the John Guest fitting marked ‘Gas
IN’ Then connect the threaded end to the regulator,
taking care not to lose the plastic olive located inside
the threaded nut. To turn the gas ON, rotate the
regulator knob clockwise to the end-stop.
Turn the knob fully anti-
clockwise before fitting
CLOSED