Product Sheet

A. Location
Tap must be positioned so that it drains into a
suitable sink. Tap should be situated as closely
as possible to directly above the under-sink G4
Command-Centre. Maximum distance from the
base of the tap to the G4 Command-Centre
is one metre (may be extended if required). G4
Command-Centre must have clearances as
shown on the drawings. Ventilation accessories
(supplied) must be installed as per instructions.
B. Plumbing
Must be installed in accordance with
AS/NZS3500 plumbing regulations. Designed
for direct connection to a potable (drinkable)
cold water supply with minimum pressure of 172
kPa. A 500 kPa pressure limiting valve and dual
check valve are fitted internally to comply with
AS/NZS3500. An isolating valve should be fixed
between the water supply and the under-bench
G4 Command-Centre.
C. Electrical
Designed to be connected to a 10 amp GPO,
240-230 volt AC power supply in accordance
with AS/NZS3000 wiring regulations.
D. Carbon Dioxide
The CO
2
gas cylinder (supplied) must be secured
in a suitable location using the strap provided.
The gas regulator (supplied) must be fitted. Each
cylinder contains 1 kg of CO
2
and should be
installed in a well ventilated area or a room of not
less than 38 cubic metres. See website for gas
cylinder MSDS sheet giving a complete list of
CO
2
warnings.
Caution
In some hard water areas where mineral
scale accumulation can become a problem,
consideration should be given to the
maintenance required. All G4 Command-Centre
units come with an internal bypass to simplify the
connection of an added high capacity filtration or
water softening system.
Warranty
Five year warranty.
Appliance warranty 36 months
plus additional 24 months tank
warranty. See website for details.
Accessories
91290 – Zip 0.2 micron replacement filter
91295 – Zip CO
2
cylinder twin pack
Standard tap finish: bright chrome.
Brushed chrome or black also available.
Call Zip for details and a quotation.
Technical Assistance
Zip Heaters (Aust) Pty Ltd
67-77 Allingham Street
Condell Park NSW 2200
Free Call 1800 638 622
www.zipindustries.com
As Zip policy is one of continuous product
improvement, changes to specifications may
be made without prior notice. The terms ‘Zip’,
‘HydroTap’, ‘Power-Pulse’, ‘Free-Flow’ and ‘G4
Command-Centre’ are trade marks.
Note: Zip HydroTap All-In-One “mains”
models are designed to be connected to
both hot and cold incoming water supplies.
For alternative models connected only to
cold incoming water supply, mixing boiling
and cold water to provide a limited supply of
hot water for plate rinsing, refer to “vented”
models.
ø
50 mm diameter hole
50 min.
280
50 min.
Inlet Vent
162 reach
Mains cold water
isolation valve
(not supplied)
ø
CO
2
Cylinder
1.0 Kg
104
399
Hot water from
domestic heater
(not supplied)
Clearance
Envelope
Residential Specification Sheet | Z0772 June 2014
Order Code Zip Model Rating (kW) @ 230 V Cabinet Dimensions W x D x H (mm)
HT1790 Zip HydroTap G4 AIO BCSHA “Mains” 1.7 280 x 455 x 333
Zip HydroTap
®
G4 All-In-One BCSHA “Mains”
Boiling | Chilled | Sparkling | Filtered | Instantly | Hot + Cold