ZIP HydroTap G4 ® User Guide • • • Tap Operation...................(Pages 2-8) LCD Screen & Menu .......(Pages 9-20) Maintenance.................... (Pages 21-24) Date of Installation............../.........../.......... BC Compact ON - OFF Switch Affix Model Number Label Here 802254 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.
3. Tap Safety The safety lock feature is provided to prevent boiling water flowing if the hot lever is inadvertently operated. This function can be activated and deactivated from either the Tap or from the touch screen display (Located on the unit in the cupboard). To set the tap safety setting: (Classic & Elite) 1. Press [MENU] button for main menu. 2. Press [Setting] button. 3. Press [Safety] button. 4. Press button A -YES / NO to allow or disallow the safety setting to be changed on the tap.
. Tap operation To dispense chilled water: Classic Tap HydroTap Classic: Depressing the “Blue” lever allows the dispensing of chilled water.Pulling forward the Blue lever allows the tap to operate in a “no-touch” mode. Water will flow from between 5 and 15 seconds (This is user adjustable). To reset, return the handle to the “Off” position and repeat the step. The lever has to be manually returned to the “Off” position.
3. Tap operation To dispense Boiling water: (With the safety ON) HydroTap Classic: Depress the Red lever, while simultaneously covering the safety lock button with a second finger. These two actions need to occur simultaneously within 2 seconds for the successful dispensing of boiling water. Elite Tap: Place a finger on the safety lock, then touch the boiling button, while keeping both fingers in position. HydroTap Arc/Cube: Tap the select button until the indicator light turns RED.
Tap functions HydroTap Arc/Cube: 3. On powerup, wait 30secs. for the unit to calibrate before selecting either the Boiling (RED) with safety, or Chilled (BLUE) water mode, by tapping the select button. The Arc/Cube control may be rotated in a forward or reverse direction to dispense Boiling or Chilled water. The rotary control is spring loaded in the anticlockwise direction and when released, will return to the OFF position. Rotary control When rotated clockwise the tap operates in a “Pot fill” mode.
3. Tap functions All-In-One Tap: The top of the All-In-One tap is operated the same as a Classic HydroTap. The two levers are used for dispensing boiling and chilled water. The safety button operating in the same way as on the HydroTap. The Mixer tap lever is operated as a classic ‘Flick Mixer’. The hot side is marked with a red mark and the cold side with a blue mark, for dispensing cold to warm water. Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate.
Tap lights Red Lights Blue Lights Red Boiling Water Light: (All) On all the time: This indicates that the boiling water is ready. Flashing slowly: This indicates that the boiling water is below the desired temperature. Wait for the light to stop flashing before dispensing water. The flashing light will typically occur after switching on, or coming out of sleep mode.
Filter Lights Filter Light Filter light: Classic & Elite Filter Light Off: This indicates the filter is operating within its normal specified lifespan. Filter Change light flashing slowly: The light will flash slowly when the filter is due for replacement and the LCD will show “Filter Change”. Refer to “Replacing the filter” in section ‘C’ of this document.
3LCD Screen Zip HydroTap introduces a ‘TOUCH’ screen for easy setup and operation adjustment. Other possible messages in status window: Status** Information Notes Safety OFF Product is in normal operation mode - Safety ON Safety lock is activated Refer to section G - safety System Fault Product has one or more system faults Refer to section B Sleep Mode System is in sleep mode. Boiling Refer to section water or hot water is not available.
3LCD Main Menu Language Screen Menu Sub Menu Sub Menu Options • English A • Deutsch Information Section • Product Info • Product serial No.
A LCD Screen operation - Section A Set Language 1. Press [MENU] for main menu. 2. Press [Language] button. 3. Select the country to change the language 4. Press [<=] button for the previous menu LCD Screen operation - Section B B System Information In this section, you can find your product serial number , check system fault messages or view the event logs of your product. 1. Press the [MENU] button for main menu. 2.
LCD Screen operation - Section C Install C Once your Zip HydroTap G4 unit has been installed, Go to Install menu to configure the system settings for your product. Sub menu: 1. - Filter Flush 2. - Filter Reset 3. - Boiling Calibration 4. - Booster 5. - Lux Sensor Calibration 1 - Filter Flush Have a 10L bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the Filter Flush Mode is in operation.
LCD Screen operation - Section C 2 - Filter Reset After replacing the filter, the counters should be reset 1. Press the [MENU] button for main menu. 2. Press the [Install] button. 3. Press the [Filter Reset] button. 4. To set the filter life or edit filter usage, refer to section G- Filter. 3 - Boiling Calibration NOTE: Occasionaly the system will vent steam from the tap. This is normal operation as HydroTaps are programmed to re-calibrate at regular intervals.
LCD Screen operation - Section C 5 - Lux Sensor Calibration NOTE: Conduct calibration under normal light conditions 1. Press [MENU] button for main menu. 2. Press [Install] button. 3. Press [Lux Sensor Calibration] button. 4. The lights on the Tap head will flash to confirm calibration. 5. Check for correct tap operation by selecting ‘Lux Sensor-> OFF’. When the room is darkened (below the calibrated light level), the tap lights will turn OFF after 24 seconds.
3. E LCD Screen operation - Section E Security The Zip HydroTap G4 allows the appliance coordinator to set up a password to protect against users changing the preferred system settings. To set a password 1. Press [MENU] button for main menu. 2. Press [Security] button. 3. Press [Enable Password} 4. Enter a 4 digit password To change a password 1. Press [MENU] button for main menu. 2. Press [Security] button. 3. Press [Change Password} 4. Enter your old 4 digit password 5.
3. LCD Screen operation - Section G g Instructions G Settings If, in section E, you have set a password, then you will need to enter your password to access the settings screens. If you have forgotten the password, please disconnect the power and restart your HydroTap unit. 1. Press [MENU] button for main menu. 2. Press [Settings] button. 4. Then enter your 4-digit password. Set Date / Time G4 HydroTap Set Date/Time Screen 1. Press [MENU] button for main menu. 2. Press [Setting] button. 3.
3. LCD Screen operation - Section G tions 1. Press [MENU] button for main menu. 2. Press [Temperature] button. 3. To adjust the temperature, press the relevant temperature button and then use the up and down arrows. Filter Zip HydroTap G4 allows the user to adjust filter life and edit filter usage. Note: The filter life may be set as a function of Litres used, or in months from the filter change. When the first of these functions is reached (i.e.
LCD Screen operation - Section G 3. Energy Modes This mode allows the HydroTap to Go into Energy Saving mode. There are two options available: ‘Sleep’ mode and ‘ON/OFF’ mode. In Sleep Mode the unit will Go to “Sleep” after a 2hr period of inactivity. The Boiling water will gradually drop to either 68°C or room temp, as shown in the table below and the Chilled water will be ON or OFF. When the period of inactivity passes, the home screen status window will show “Sleep Mode”. To activate the sleep mode: 1.
LCD Screen operation - Section G Note: Any attempt, during OFF mode, to dispense water, will bring the unit out of sleep mode. The unit will return to sleep mode after 2 hours of non use. Please allow sufficient time for the water to reach the set temperature after disabling the sleep mode. In ON / OFF Mode the user may turn the unit ON or OFF at specific times for individual days or alternatively by weekly and/or weekend settings. To activate ON/OFF mode: 1. Press the [MENU] button for main menu.
LCD Screen operation - Section G Safety To set the tap safety setting: • Press [MENU] button for main menu. • Press [Setting] button. • Press [Safety] button. • Press button A - YES to allow the safety setting to be changed A B C * To Enable or Disable the safety on the tap • Press button B to select Enable / Disable Note: When NO is selected the safety lock B cannot be changed from it’s current setting. To change the safety settings, first select YES before making the change.
LCD Screen operation - Section G Dispense Times This gives you the ability to change the maximum dispensing time for both the hot and cold water. The default settings for the maximum dispensing times is 15 seconds. Here, the operator may change both the hot and cold dispensing times to between 5 and 15 seconds, in increments of 1 second. To edit the dispensing times: 1. 2. 3. 4. Press [MENU] button for main menu. Press [Setting] button. Press [Dispense Time] button.
Filter Maintenance • Caution: a small amount of water will drip as the cartridge is removed. • Do not tilt the cartridge as water may spill from it if tilted. • Unpack replacement cartridge and remove sanitary cap, write today’s date where shown on the label. • Avoid touching the filter O-rings and filter opening as this may cause bacterial contamination of the cartridge.
Home Menu Icons Safety switch is LOCKED. The HydroTap will not dispense any Boiling water. See page 20 for safety switch operation Safety switch is UNLOCKED. Boiling water may be dispensed. See page 3 for tap operation details Sleep mode is active. There are 7 sleep mode options which display this icon on the home screen. See page 18 for details. Heater is in OFF mode. When this icon is displayed, no power is being supplied to the heating element. See page 18 for Energy Mode options.
Cleaning General cleaning Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft damp cloth and mild soap. Under sink units must never be located near, or cleaned with water jets. Avoid using air bourne pesticides near the undersink unit. Contact Details Head Office Zip Heaters (Aust) Pty. Ltd. ABN: 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia Website: www.zipindustries.