Installation and Operating Instructions Zip HydroTap Miniboil ® Boiling and Ambient drinking water for kitchens and the home. Miniboil BA tap HydroTap Classic BA tap Affix Model Number Label Here 89585 GP Zip HydroTap Installation and Operating Instructions - 89585 - March 2016 v2.
This page intentionally left blank Page 2 of 16 Zip HydroTap Installation and Operating Instructions - 89585 - March 2016 v2.
Check List Before Installation: A. Read the instructions. B. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied. C. The pressure limiting valve must be fitted as part of the kit. D. Check the water quality to determine if extra filtration will be required. E. Check the appliance rating plate and ensure correct power is available for the appliance. F.
Contents Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Read These Warnings First. . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Models covered by these instructions . . . . . . . . . . . . . . . . . . 6 Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Special tools required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read These Warnings First Safety This appliance is not intended for use by persons (Including Children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance Qualifications If any power cord or plug is damaged it must be repaired only by a qualified technician.
# Section Heading Read These Warnings continued Frost Protection If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework and fittings. Installation Environment Considerations This unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature.
Special Tools Required In addition to normal tools, the following will be required: • 35mm diameter sheet metal hole punch for sink tops. (not supplied) • 35mm diameter hole saw for timber bench tops. (not supplied) • Nut runner tube spanner (supplied) for fixing tap assembly. When installing a Font unit: • 108mm diameter sheet metal or hole saw to suit surface being cut. Installation Procedure Fixing nut Black spacer Step A - Installing the tap 1.
Installation Procedure continued Step B - Installing the undersink unit This instruction is critical : Adjust both cupboard door hinges and attach the supplied rubber door buffers to the doors to create a 4 mm air-gap between the doors and the cupboard. This is the minimum ventilation requirement for low usage installations. Proper air circulation is important for efficient running of the Hydrotap models. Therefore cupboard ventilation for Hydrotap models is recommended.
Installation Procedure continued - Fit the pressure limiting valve to the outlet side of the isolating valve (not supplied). Fig.2 - Flush Valve ON Open position - Mount the filter and flush valve assemblies in a convenient position using the angle bracket supplied. Connect the filter assembly plumbing between the pressure limiting valve and the inlet of the undersink unit, using the ¼” JG fittings supplied (see Figure.1 on page 8).
Installation Procedure continued John Guest (JG) fittings - Assembly and Removal Step F - Testing and commissioning Boiling The unit is now running in normal operating mode. The Red LED will flash until usable temperature is reached. Before using the HydroTap wait 5 minutes after this point to allow adequate fill time. The unit is now ready for use. Test water delivery from the tap and check for appropriate temperatures. Use cable clips to tidy and secure wiring.
Operating the touch Tap • • To dispense boiling water touch the Red Markers + Safety Lock simultaneously. To dispense ambient water touch the blue markers. Red Boiling Water Light ON all the time: Flashing Fast: Flashing Slowly: This indicates boiling water is ready to be dispensed. This indicates the boiling water is below usable temperature and the Sleep Mode is OFF. This indicates Sleep Mode is active.
Operating the Classic lever Tap Boiling Filter Change Red Boiling Water Light On all the time: This indicates that the boiling water is ready. Flashing Fast: This indicates the boiling water is below usable temperature and the Sleep Mode is OFF. Flashing Slowly: This indicates Sleep Mode is active. . Filter light Filter Change Light Off: This indicates the filter is operating within its normal specified lifespan.
Font Installation Procedure A font kit installation is available for this product and is sold separately as an accessory. For details of the available font kits, please contact your Zip customer service provider. The font instalation instructions and mounting template are supplied with the font kit. Font Kit Part No. 90915 Font Kit Miniboil Elite 90046 Font Kit Miniboil Classic Trouble Shooting Symptom Possible Cause Solution No LED display, no tap head lights or, no water when tap is operated.
Cleaning Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft cloth or brush and mild soap and water. Do not spray water over the tap as it may damage the low-voltage electronics. Undersink units must never be cleaned with water jets. End of life disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details.
Notes Zip HydroTap Installation and Operating Instructions - 89585 - March 2016 v2.
Contact Details Head Office Zip Heaters (Aust) Pty. Ltd ABN: 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia Website: www.zipheaters.com Facsimile: (02) 9796 3858 Telephone: (02) 9796 3100 Free Call: 1 800 638 633 WMKA00099 AS 3498 As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods.