Specifications Sheet
Zip Specification Sheet - Z0219 13.01.21
Order
Code
Zip
Model
Boiling
Water
Cold
Water
Boiling Chamber
Total
Rating
Under-Sink
W x D x H
HT1006 Miniboil BA Classic Yes Yes 1.8 litres 1.5 kW 212 x 272 x 338
Location
The Zip Miniboil Tap may be installed to ow
into a sink, or be installed away from a sink
on a Zip Miniboil “font” accessory which is
plumbed to waste.
For tap installations a 35 mm hole is required.
Electrical
Plugged to a 10 Amp GPO within 1000 mm.
Power supply 220 V to 240 V AC 50/60 Hz.
Install in accordance with AS/ NZS 3000
safety regulations.
Clearances
The under sink system must be installed with
clearances of 50 mm left and right, 200 mm
above and 60 mm rear.
Plumbing
Must be installed by a qualied technician in
accordance with instructions supplied with
the product and with AS/NZS 3500 plumbing
regulations.
Water supply must be potable (drinkable), with
a minimum pressure of 172 kPa.
The unit comes complete with a pressure
limiting valve, an isolation valve (not supplied)
must be installed between the water supply
and the under sink system.
The under sink system must be located
directly beneath the tap. The maximun
distance from the tap to the undersink unit is
1000mm. Under sink tubing must be taut with
constant ow for proper drainage and never
be looped or coiled.
Warranty
Twelve months full parts and labour warranty.
For full warranty details visit
www.zipindustries.com
Accessories
90046 - Tap Font Kit for including tap extension
for Classic models
90026 - 100mm Tap Extension
91290 - Zip 0.2 micron replacement lter
Technical Assistance
Contact Zip Industries (Aust) Pty Ltd
67 Allingham Street,
Condell Park NSW 2200.
Free Call 1800 638 633
Telephone 02 9796 3100
Website www.zipindustries.com
As Zip policy is one of continuous product
improvement changes to specifications may
be made without prior notice.
212
46
125
50 min
50 min
200 min
196
A
A
Mains Cold water
isolation valve
240 - 230V, 50Hz
GPO
Clearance
Envelope
Pressure limiting valvle
Filter
269
338
65 min.
SECTION A-A
SCALE 1 : 5
Clearance
Envelope
4 min.
Buffer Pad
Air Space
80
15
35 Hole
HydroTap®
Miniboil Classic
Tap
Sink shown only
94
154
219
6
92
C
L
Reach
232
297
DETAIL FONT
SCALE 1 : 5
Specification Sheet – Model HT1006
Zip HydroTap
®
Miniboil
®
Classic
Super-compact economy models for
filtered boiling water and filtered ambient water
The terms, Zip, HydroTap, Miniboil and Power-Pulse are Trademarks