Installation and Operation Guide

14
Quick Start Installation Guide
807119 v1.00 01.21 G5 BCS Quick Start Guide
Use a 6mm Allen key or a
large flat-blade screwdriver
to adjust the valve.
Rotate the adjustment screw
anti-clockwise to increase,
and clockwise to decrease
the flow.
To measure the set flow rate, use a measuring jug or cup and run the
sparkling water for 15 seconds. The HydroTap has a default 15 second
dispense time, which will help in your flow rate setup.
Multiply the amount of water dispensed in 15 seconds by 4 to determine
the flow rate in litres per minute.
The optimum flow rate is 1.6 litres per minute (400ml per 15 seconds).
If the flow rate is adjusted too high, the carbonation tank will be emptied
of water, leaving only CO
2
to be dispensed from the tap. This will result in
inconsistent flow (spluttering).
SECTION 7: Fit the carbonation valve
+
-
White tube to SPARKLING outlet
of Command Centre
Carbonation valve flow adjustment
Celsius
AiO Arc
Other
sparkling
AvoidClassic, Wave,
Classic Plus,
Elite