Installation and Operating Instructions Zip Filter Tap Cold Water Filtration (unchilled) Affix Model Number Label Here 801085 Zip Filter Tap - Installation & Operating Instructions - 801085 - November 2012 v1.
R Read These Warnings First Please read all Warnings, Installation Requirements and Installation Instructions before installing any Zip Filter Tap. These appliances are not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliances by a person responsible for their safety.
# Installation Instructions 1 1 Filter cartridge insertion Filter cartridge removal 2 2 Installing the Filter Tap Position the Filter Tap at the back of the sink where there is a 45 mm wide flat area within the draining areas of the sink. The recommended position is over one corner of the bowl. Make sure the selected position allows the spout to overhang the sink bowl. The cutout size is 25 mm. Mark the centre of the new Filter Tap position on the sink with a centre punch.
Installation Instructions # Installing the DNR Multifunction Valve The DNR valve must be inserted into the tube between the main isolation valve and the filter cartridge. Ensure the flow is in the correct direction. The DNR valve must be connected downstream of an accessible isolation tap. The 3/4”F- BSP threaded section on the inlet end of the DNR valve may be connected directly to an isolation tap.
Installation Instructions # NOTE: When flushing the system, some black particles may be released into the water. This is normal. The water will become clear after the first few litres. Complete the installation and leave these instructions with client. Service All service work must only be carried out by a suitably qualified and experienced service person. Before calling for service, check the water supply is turned ‘ON’ and OK.
Performance Data Part Number 91289 Performance Data Sheet Use Replacement Catridge 91289 The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and NSF/ANSI Standard 53. Capacity: 3,785 litres Contaminant Reduction Determined by NSF testing. Test Conditions: pH7.5, Pressure: 415 kPa, Flow Rate: 1.
Notes Zip Filter Tap - Installation & Operating Instructions - 801085 - November 2012 v1.
Contact Details Head Office Zip Heaters (Aust) Pty. Ltd. ABN: 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia Website: www.zipheaters.com Facsimile: (02) 9796 3858 Telephone: (02) 9796 3100 Free Call: 1 800 638 633 As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods.