Specification Sheet

Water Pressure
Water Connection
Integral Water Values
Water Supply Requirements
Total Dissolved Solids (TDS)
Integral Water Filter
Power Rating
Power Supply Requirements
Dimensions (WxDxH)
Minimum Air Gap
Dry Weight
Product Approvals
Warranty
COMMAND CENTER SPECS
Min 30psi – Max 75psi with a minimum ow rate of 1 gpm
½” BSP - isolation valve is required within 3’ of the installation
HydroTaps are tted with a Dual Check Valve and a 50psi Pressure Limiting Valve
Potable drinking water supply
TDS Min 50ppm – Max 120ppm
0.2 micron, 1 size - Replace every 1,500 gallons or 12 months
110-120V, 60 Hz, 1.18kW
110-120V, 60Hz 15 amp power supply with a NEMA 5-15 outlet
13.4” x 18.1” x 13.1”
Clearances are required - 2” Left side , 2” Right side , 8”Above
53lbs
WQA - NSF/ANSI 372, 42 & 53, cUL, CEC
2 years (1 year Limited Warranty plus additional 1 year Warranty is available on product registration)
Installation and connection of your HydroTap must be carried out by a qualied person, observing all local, state, & federal regulations. You will require suitable 110 -120V 60Hz 15 amp power supply with a NEMA 5-15
electrical outlet within 3’ of the product. The HydroTap is an air-cooled system, so discrete cabinetry cut-outs are required for ventilation. Installation on most counter tops is straightforward, however some stone
counter tops may require a specialized cutting service. If using a drip tray (font) accessory, suitable drainage to a trapped waste is required within 3’ of the installation. If you live in an area with hard water (more than
120ppm), we recommend installation of a scale ltration kit. Sufcient space and clearance to install the HydroTap as detailed in the product installation guidelines is required. Installation by Zip Professional Service
can be arranged with a phone call to 1-833-233-2358 or through www.us.zipwater.com
HYDROTAP
®
CUBE FOR HOME
A
A
1
8
SECTION A-A
3mm ( )
buffer pad
air space
(461
mm
)
18.1"
IEC Flex & Plug
110-120V, 60Hz
power outlet
Position the Tap to dispense into the sink
bowl with ample clearance for a cup or a carafe.
Alternatively, the Tap may be mounted away from
the sink using a Zip Font, available as an accessory.
Sample
Tap
Clearance
Envelope
Mains cold water
isolation valve
(not supplied)
1
8
8 "
(207mm)
DETAIL B: CABINET FLOOR CUT-OUT
VENTILATION DETAIL
See Detail B
(333mm)
13.1"
min
7.9"
min
(200mm)
1 "
hole
Sink shown only
3
8
(35mm)
11
16
1 " max
15
16
12
"
(326mm)
3
16
"
(5mm)
(43mm)
2.0"
min
(50mm)
2.0"
min
(50mm)
13.4"
min
(339mm)
19ZIP016_CubeBC_240v_v1