User Manual
08 806143 - CW ChillTap UCCT 10.18 v1.03
Installation instructions
Chiller Installation
Place the chiller unit into the cupboard with the proposed outlet tap position as close as possible, to minimise the length of
tubing exposed between the chiller unit and the outlet tap. Arrange tubes in the most direct route between tap outlet and unit.
The tubing length is limited to 1000 mm.
Mains Water Connection
Note: Install an isolation valve (not supplied) in the water supply line before the connection to the product.
Connect the braided hose to the isolation valve installed in the mains water supply line. For best results, the recommended
minimum static pressure is 250 kPa (2.5 bar).
Connect the braided hose from the isolation valve to the top of the undersink unit, marked MAINS IN (see Fig.5).
On / Off Switch
If caps are removed to allow lifting handles
to be installed during installation of the unit,
ensure they are retted when unit is in position.
Water Connection
for ChillTap
Water Connection
for ChillTap Extra
Fig.5