Installation instructions & user manual Zip ChillTap Filtered, chilled water on tap. 806143 - CW ChillTap UCCT 10.18 v1.
Table of contents ChillTap Specifications Before Installation............................................................................................................................ 3 Warnings and Precautions............................................................................................................... 3 Technical Specification.................................................................................................................... 4 Installation Requirements...................
Before installation A. B. C. D. E. F. Read the instructions. Note: All fittings are supplied with the appliance kit except an isolation valve. Check the water quality to determine if extra filtration will be required. Check the appliance rating plate and ensure correct power is available for the appliance. Check the underbench cupboard supporting the appliance is adequate for the total weight and size of the appliance.
Technical specification Model Water supplied Power Refrigerant Rating (kW) ChillTap 60 glass Chilled ChillTap Extra 60 glass Chilled, Ambient ChillTap 140 glass Chilled ChillTap Extra 140 glass Chilled, Ambient 0.3 0.3 0.3 0.3 R134a R134a R134a R134a Dimensions Dry Weight* W x D x H (mm) (kg) 280 x 475 x 335 280 x 475 x 335 280 x 475 x 335 280 x 475 x 335 25 25 25 25 Note: The standard glass is 200 ml (7 fl oz). * Add 4kg when filled with water.
Installation instructions Tap Installation In addition to common tools, the following will be required: O-RING NUT Blue and Red tubes to Tee piece which connects to Vent Outlet. White tube to Chilled Outlet • 25mm (ChillTap Standard/Heavy Duty) OR 35mm (ChillTap Extra) diameter sheet metal hole punch for sink tops (not supplied) • 25mm (ChillTap Standard/Heavy Duty) OR 35mm (ChillTap Extra) diameter hole saw for timber bench tops (not supplied) Position the Tap Warning: Do not reuse old hose-sets.
Installation instructions Ventilation When installing air flow ducts, the following tools will be required: • Jigsaw and 12 mm drill. • Keyhole or Wall Board saw. Ventilation Requirements IMPORTANT! Allow clearance of 50 mm around and 200 mm above the chiller unit. Proper air circulation must be provided for the system to operate correctly. Both the top and the front of the chiller must remain accessible for servicing. Fit the 3 mm silicon door buffers to the inside edge of the cupboard door (Fig.3).
Installation instructions 12 .00 285.00 A - KICKBOARD CUT-OUT 314.00 B - CABINET FLOOR CUT-OUT 5 .00 12 12 .00 = 60.00 = 1.Drill 4 pilot holes Ø12 in corners 2.Finish cut-out using Jigsaw and Keyhole or Wall Board saw max 43 326.00 1.Drill two pilot holes Ø12 2.Finish cut-out using Jigsaw 45.00 C - CABINET FLOOR CUT-OUT B A Note: Ensure that A and B are positioned at opposite ends of the cabinet. Fig.4 284 C 12 1.Drill 4 pilot holes Ø12 in corners 2.
Installation instructions Chiller Installation Place the chiller unit into the cupboard with the proposed outlet tap position as close as possible, to minimise the length of tubing exposed between the chiller unit and the outlet tap. Arrange tubes in the most direct route between tap outlet and unit. The tubing length is limited to 1000 mm. Mains Water Connection Note: Install an isolation valve (not supplied) in the water supply line before the connection to the product.
Installation instructions ChillTap Standard BLUE ChillTap Heavy Duty 1. Remove plugs from the outlet fittings on the top of the undersink chiller unit by depressing the collet and simultaneously pulling out the plug. 2. Measure and trim the three 1/4” coloured hoses from the carafe tap to the outlet fittings on the top of the chiller unit. See Fig.6 and Fig.7. 3. Before making the connections, insulate the hoses with the loose length of foam insulation.
Operation & Maintenance Operation ROTATE Chilled filtered water (blue) (ChillTap Extra) Ambient water (white) REMOVE FILTER 1. ROTATE 2. PULL DOWN To dispense chilled, filtered water, rotate the lever on the right hand side of the carafe tap to a horizontal position. The lever will spring back when released. ChillTap Extra: Chilled still filtered water is dispensed using the lever on the right hand side of the carafe tap (blue marking).
Troubleshooting Prior to any fault finding, please ensure all water connections to the chiller are sound and that the incoming water supply is turned on. Also ensure that all electrical connections to the chiller are secure and that the chiller has had adequate time to cool down. Call a licenced electrician, plumber, or Zip free call in Australia on 1800 460 222, for assistance, service, spare parts, or enquiries.
Head Office Zip Water (Aust) Pty. Ltd. ABN 46 000 578 727 67-77 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia www.zipwater.com Telephone (02) 9796 3100 Sales Free Call: 1800 638 633 Service Free Call: 1800 460 222 The terms “Zip” and “ChillTap” are registered trade marks of Zip Water (Aust) Pty Ltd. Zip products described in this publication are manufactured under one or more patents and further patent applications are pending.