Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Instructions for the user These appliances deliver water not exceeding 50 ºC in accordance with AS3498.
1. Overview When ordering spare parts, please always specify the appliance model and serial number. 4 5 6 1 2 7 3 Pos. Part.-No. Description Pos. Part.-No. Description 1 2 Hood with control panel MCX heating cartridge 3.5 kW / 230V MCX heating cartridge 4.4 kW / 230V MCX heating cartridge 5.
Contents 1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. Environment and recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3. Safety instructions Installation, initial operation and maintenance of this appliance must only be conducted by an authorised professional, who will then be responsible for adherence to applicable standards and installation regulations. We assume no liability for any damages caused by failure to observe these instructions. • Do not use the appliance until it has been correctly installed and unless it is in perfect working order.
4. Technical specifications Type Part no. Capacity (Liter) MCX 3 27300 0,2 Nominal pressure MPa (bar) 1 (10) MCX 6 27600 0,2 1 (10) 1 (10) IES system bare resistance element Heating system Required water resistance at 15 °C in cm Electric supply Nominal power rating Nominal current Temperature choice Factory temperature setting Maximum inlet temperature Factory flow setting at 0.3MPa (3 bar) 2,0 l/min Maximum temperature 2,5 l/min increase at rated power 3,0 l/min and a flow rate of......
5. Typical installations Vented installation with special open outlet tap Flow controller MCX 3/4 : CSP 3 MCX 6 : CSP 6 Electrical connection with mains power cable (shorten if necessary) 6 Instructions for user - 9120-15002 - MCX - 801052 - March 2012 v1.01 Dimensions in mm Top edge of wash basin approx.. 850 Angle valve approx. 550 Axis wall bracket approx. 520 Cable entry approx.
5. Typical installations Unvented installation (closed outlet) with tap for pressurised appliances Flow controller MCX 3/4 : CSP 3 MCX 6 : CSP 6 Dimensions in mm 7 Instructions for user - 9120-15002 - MCX - 801052 - March 2013 v1.01 Angle valve approx. 550 Axis wall bracket approx. 520 Cable entry approx. 553 Angle valve G 1/2“ Top edge of wash basin approx..
6. Description of applicance The Zip instantaneous water heaters are compact electronically controlled water heaters. It is intended to provide economical heating of water for a wash basin when installed together with a sanitary water fitting. When the hot-water tap is opened, the heater switches itself on automatically when the minimum water flow rate is exceeded and heats the water as it passes through the appliance. There are 3 available temperature settings, 35ºC, 38ºC and 45ºC (Max).
8. Additional features Activate / De-activate LED display As part of the appliance’s energy saving feature, the active LED will automatically turn off 20 seconds after the last operation (e.g. tapping or temperature selection). To identify the current / selected setting at any time, the LED display can be enabled permanently therefore disabling the LED standby function: • Turn off the water at the outlet from the appliance. • Press and hold the “Touch” key for at least 7 seconds.
9. Maintenance • The appliance and fittings should only be cleaned with a damp cloth. Do not use abrasive or chlorine-based cleaning agents or solvents. • Keep the control panel area dry! • Clean the jet regulator regularly and replace as necessary. • Dirt and scale deposited in the pipes and appliance will affect its function. Typical indications of this are a reduced flow rate or noisy flow.
Instructions for user - 9120-15002 - MCX - 801052 - March 2013 v1.01 11.
Zip Heaters (Aust) Pty. Ltd. ABN: 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia Website: www.zipheaters.com Facsimile: (02) 9796 3858 Telephone: (02) 9796 3100 Free Call: 1 800 638 633 As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods. 12.