Commissioning
1. Close the circuit breaker to connect the electrical supply.
2. Check everything is working as it should and the water temperature is achieving the desired temperature. If not follow the guide below to
correct the temperature.
8. Commissioning
Adjustment of the flow rate is to be done by a Qualified Technician.
Adjustments are done by turning the adjusting screw located under the appliance’s cover.
9. Flow rate adjustment
Removing the cover
The rating plate and the adjusting screw for the flow rate is located under the cover.
1. Push the cover on the corrugated side towards the wall bracket.
2. At the rear corners press the cover down (A) until the front edge lifts (B).
3. Remove the cover by pulling forward and upwards.
A
A
B
Replacing the cover
To replace the cover, reverse the process as described in the process for removing the cover above.
1. Push the cover flat towards the wall bracket under the edges of the water connections.
2. Press down the front edge of the cover and push it forward again at the rear edge until it fits.