Product guide

Zip AquaFlo II
®
Unvented water heater
Unvented stainless-steel cylinders
90 to 300 litre capacity
Construction
• Direct, indirect and solar compatible
unvented water heaters.
• Corrosion resistant Duplex Stainless Steel
cylinder.
• High performance, low profile coil-in-coil
heat exchanger.
• High performance CFC free injected
polyurethane foam insulation.
• White plastic coated steel case resistant
to scuffs and damage.
External expansion for reliability and ease
of maintenance.
• Cylinder pressure tested to 15 bar.
Installation
For installation by a qualified installer in
accordance with all national and local
Building Regulations.
Intended for floor standing only – refer to
Technical Data for weight when full.
Nominal Capacity
Direct and Indirect units: 90, 120, 150,
180, 210, 250 and 300 litres.
Solar Twin Coil and Solar Direct units: 150,
180, 210, 250 and 300 litres.
Immersion Elements
Incoloy construction 1¾” thread. Length
14” Loading 3kW @ 240V.
Heat Exchanger
22mm low profile, high efficiency stainless
steel coil-in-coil.
Features and benefits
Wide range of capacities from 90 litres up
to 300 litres.
High grade Duplex Stainless Steel Unvented
Cylinder for long life.
Incoloy immersion elements provide excellent
corrosion resistance.
Titanium replacement elements available for
high use applications.
Compact coil-in-coil heat exchangers provide
fast heat up and recovery.
Multi-element options for faster heat up.
High performance insulation ensures
minimum heat loss.
External expansion for optimum reliability,
more usable space and ease of
maintenance.
No sacrificial anode. Avoids the need for
regular inspection.
22mm compression connections for ease of
installation.
Cylinders tested to 15 bar.
25 year transferable cylinder warranty.
2 year warranty on all other components.
Fully approved to UK Water Regulations and
Buildings Regulations Part G3 and Part L.
90 91
Controls
Thermostat – adjustable up to 65°C.
Over temperature safety cut-out –
Re-settable. Operates at 85°C.
Expansion relief valve – 6 bar.
Temperature and pressure relief valve –
90°C and 7 bar.
Tundish.
Two way valve with indirect models.
Pressure reducing valve – 3 bar.
Expansion vessel – Pre-charged to 3 bar.
Plumbing
For connection to 22mm mains potable
water supply.
Minimum water supply 1.5 bar, 20 l/min.
Maximum water supply pressure 12 bar.
Electrical
To be wired to a suitably rated double pole
fused spur.
Installation must comply with current IEE
regulations.
Approvals
KIWA approved to UK Water Regulations.
KIWA approved to UK Building Regulations
Part G3 and Part L.
Immersion element/thermostat BEAB
approved and CE endorsed.
Warranty
25 years on cylinder transferable
(conditions apply).
2 years on all other components.
Hot water
Hot water