Product guide
75
74
Zip InLine
® 
CEX
Over and Undersink Electronic
Instantaneous Water Heaters for 
Single or Multiple Outlets
* Subject to a minimum water pressure of 2 bar and maximum of 10 bar
Features and benefits   
•  The most energy efficient way   
of heating water electrically.
•  Highly efficient bare wire heating 
system.
•  Zero standing heat loss as no stored 
water.
•  Instant hot water.
•  Provides a constant* supply of hot 
water at exactly the temperature 
selected.
•  Heating power adjusted electronically 
to compensates for variable inlet 
pressures and temperatures.
•  Required temperature can be set 
using two touch sensitive keys within 
the range 30°C to 55°C with digital 
display.
•  Maintains precise temperature 
control despite fluctuations in   
voltage and water pressure.
•  Suitable for use with preheated water 
from solar systems.
•  Power rating can be selected at time 
of installation.
•  Optional wireless control (ZL016).
•  CEX-O for oversink CEX-U   
for undersink installation.
Ratings  
6.6kW/8.8kW. Selected at installation.
Heating System 
Bare-wire system.
IP Rating  
Oversink IP25 Undersink IP24 
Suitable for Zone 1.
Approvals  
WRAS, VDE & CE endorsed.
Warranty 
1 year on site parts and labour. For full 
details visit: www.zipheaters.co.uk/warranty
Location 
The appliance must be installed in a frost 
free environment. 
In order to minimise thermal losses the 
distance between the appliance and the 
outlet fitting should be as short as possible.
Plumbing 
The appliance is intended for connection to 
a mains potable water supply. The specific 
water resistance of the supply must not 
fall below the minimum specified on the 
rating plate.
Minimum flow rate 2 litres/min.
Should be installed by a suitable qualified 
installer of electric instantaneous water 
heaters.
Electrical 
The appliance must be earthed and 
connected to the supply by means of 
permanent wiring through an isolation switch 
having a contact separation of at least 3mm 
on all poles and protected by a suitably 
rated circuit breaker.
The cross sectional area of the connection 
cable must be in accordance with the power 
rating of the appliance.
The installation must be in accordance with 
current IEE regulations.
Product 
Code
Power 
rating 
kW@230V
50
O
C Max
Flow rate 
ltrs/min
38
O
C Max
Flow rate 
ltrs/min
Temperature
setting 
range
(
o
C)
Dimensions 
W x D x H
(mm)
CEX-O 6.6 - 8.8 2.5 - 3.3 1.5 30 - 55 177 x 108 x 294
CEX-U 6.6 - 8.8 2.5 - 3.3 2.4 30 - 55 177 x 108 x 294
Technical Data
Maximum temperature increase @230V and a flow rate of:
3.0 litres/min 31ºC- 42ºC
3.0 litres/min 24ºC- 31ºC
3.0 litres/min 19ºC- 25ºC
3.0 litres/min 16ºC- 21ºC
Switch on flow rate (l/min) 2.0
Hot water
Hot water
CEX-O
CEX-U