Installation and Operating Instructions ® Zip HydroTap All-In-One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms. This Installation Instruction covers the following HydroTap residential models: Affix Model Number Label Here 89944 HydroTap Installation and Operating Instructions - 89944 - July 2011 v1.
Contents Read These Warnings First . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Special tools required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 8 Operating the Mixer Tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Mains version connections (diagrams) . . . . . . . . . . . . . . . . .
Read These Warnings First Safety This appliance is not intended for use by persons (Including Children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance Refrigerant The power point must be located within reach of its cable.
Read These Warnings continued is needed, follow the instructions on page 15 /16 or contact your Service Provider. Frost Protection If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework and fittings. Altitude The HydroTap is equipped with a self-calibrating program which caters for altitude adjustment.
Installation Requirements continued • Power supply 220-240 Volt AC, for connection to the heater via a 10 amp (160/125) or 15 amp (240/175) GPO. • This switch must provide all-pole disconnection and a contact separation of at least 3mm installed in accordance with wiring rules. • Cold water supply with a minimum working pressure of 200 kPa and a maximum working pressure of 700 kPa connected via an isolation valve. If pressure is likely to exceed 700 kPa, install a 500 kPa Pressure Limiting Valve.
Installation procedure continued Step B - Installing the undersink unit NOTE : New hose sets supplied with the unit should be used. Do not use old hose sets. SPECIAL NOTE: The HydroTap undersink units are heavy, take note of the weights listed in the table on page 4. If you think you cannot lift the unit safely, get help and avoid possible injury. Before positioning the heater connect the braided water inlet hose (supplied) to the cold water tee piece (see Pages 10-13).
Installation procedure continued Connect the tap USB connector to the USB port on the undersink unit. Orient the USB plug carefully and connect, do not force the plug. Once connected, fix the cable to the wall, ensure it is away from any possible water splashes and is off the floor. Vent line Hot line Chilled line Model: NON Vented. Connect the two braided hoses to the Hot and Cold water supply, as shown in pages 10-11.
Installation procedure continued Step D - Connecting the water supply To prevent sediment from entering the HydroTap at connection, flush water through the supply line thoroughly before connection to the HydroTap. Open the access door and check that the filter is in place and secure. Connect the water supply to the undersink unit using the attached flexible hose .Turn ON water and check for leaks. If no leaks are evident turn the power ON.
Operating the Mixer tap The Mixer tap is operated as a conventional ‘Flick Mixer’ Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Lift the handle all the way up to turn the tap off. When the handle is moved to the left, the temperature is decreased and when moved to the right the temperature is increased. The final temperature will be dependant on the temperature of the incoming cold water.
220 161.50 136 SILICONE HOSE FROM STEAM VENT IN HYDROTAP UNIT TO TAP 51 110 280 VENT OUTLET POSITION NOTE: IF THE FLOW RATE IS TOO FAST, CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL-IN-ONE TAP. INSERT THE TEFLON RESTRICTOR ABOUT 20mm INTO THE UPPER SEGMENT OF THE RED SILICON TUBE WHICH CONNECTS TO THE TAP. INSERT THE BLACK PLASTIC OUTLET BUSH BETWEEN THE TWO PIECES OF RED SILICON TUBES THAT WAS CUT.
ALL IN ONE TAP-MAINS VERSION SILICONE HOSE FROM BOILING WATER TANK IN HYDROTAP UNIT TO TAP BRAIDED HOSE BH1 FROM MAINS SUPPLY BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP BRAIDED HOSE BH2 FROM DOMESTIC HOT WATER SUPPLY MAINS HOT WATER SUPPLY (ISOLATION VALVE NOT SUPPLIED) 220 SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP MAINS AMBIENT WATER SUPPLY (ISOLATION VALVE NOT SUPPLIED) 65
SILICONE HOSE FROM BOILING WATER TANK IN HYDROTAP UNIT TO TAP BRAIDED HOSE BH1 FROM MAINS WATER SUPPLY SILICONE HOSE FROM STEAM VENT IN HYDROTAP TO TAP SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP BRAIDED HOSE BH2 FROM ALL-IN-ONE TAP TO VENTURI BRAIDED HOSE BH3 FROM VENTURI TO TAP NT VE BOILING WATER NOTE: IF THE FLOW RATE IS TOO FAST, CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL-IN-ONE TAP.
220 ALL IN ONE TAP-VENTED VERSION MAINS AMBIENT WATER SUPPLY (ISOLATION VALVE NOT SUPPLIED) 65
Operating the HydroTap Blue Chilled Water Light On all the time: Press or pull lever This indicates that the temperature of the chilled water is within the usable temperature range. Flashing slowly : This indicates that the chilled water is not at the right temperature. Wait up to 20 minutes. When the chilled water is at the right temperature, the light will stop flashing. Note: The HydroTap is designed to dispense chilled water in the temperature range 5°C to 10°C.
Replacing the Filter The Zip HydroTap notifies when filter replacement is due. The default setting is 6000 Ltrs, but this can be set in increments of 1000Ltr from 1000Ltr to 10000Ltrs. When a filter change is due, the Change Filter light will flash white once a minute and remain so until reset. A filter status light is located between the Red and Blue Lights on the tap head assembly. Depending on local water quality conditions and usage, the filter may require changing anywhere from 1000 Ltrs to 10000 Ltrs.
Setting the Energy Saver Timer (continued) Normal Operation (not available on HT boiling only series) > Set Time > > > To change time, press either Mode or Mode button until Set Time is on the display screen. Press Adjust button to increase time or Adjust button to decrease time. Time increases or decrease in increments of one minute. Hold the Adjust buttons down for rapid increases or decreases. The time will be displayed in 24Hr mode.
Setting the Energy Saver Timer (continued) Activating ‘Sleep-when-it’s-dark’ feature This feature will automatically switch the unit into Sleep mode Option 1 when the ambient light falls below a set level. For this system to operate correctly the sensor in the tap head must be calibrated for it’s surroundings. Activation: This can only be achieved through the service mode.
Boiling Water Isolation The HydroTap if equipped with a safety mode that allows protection against accidental operation by Infirm or disabled persons. 1. On the LCD scroll through the menu to Hot Isolation. < 2. Press Adjust to activate. 3. Now go to the Tap Head assembly and press the Safety Lock (3) three times rapidly, the LED’s will scroll from left to right (3) three times. This operation confirms the activation. 4. This isolates the boiling tap only. The LCD shows isolation mode is active. 5.
Cleaning Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft cloth or brush and mild soap and water. Do not spray water over the tap as it may damage the low-voltage electronics. Undersink units must never be located near, or cleaned with water jets. Trouble Shooting Symptom Possible Cause Solution No LED display, no tap head lights or, no water when tap levers are operated. No power. Plug is not located in power socket. Check power supply.
Warranty Warranty table effective from 1st January 2009.