Specification Sheet
Water Pressure
Water Connection
Integral Water Values
Water Supply Requirements
Total Dissolved Solids (TDS)
Integral Water Filter
Power Rating
Power Supply Requirements
Dimensions (WxDxH)
Minimum Air Gap
Dry Weight
Product Approvals
Warranty
COMMAND CENTER SPECS
Min 30psi – Max 75psi with a minimum ow rate of 1 gpm
½” BSP - isolation valve is required within 3’ of the installation
HydroTaps are tted with a Dual check valve and a 50psi Pressure Limiting Valve
Potable drinking water supply
TDS Min 50ppm – Max 120ppm
0.2 micron, 1.5 size - Replace every 1,800 gallons or 6 months
220-240V, 50 Hz, 2.2kW
220-240V, 50/60Hz 15 amp power supply with a NEMA 6-15 outlet
15.5” x 18.3” x 13.1”
Clearances are required - 2” Left side , 2” Right side , 8”above
67lbs
WQA - NSF/ANSI 372, 42 & 53, cUL, CEC, ADA compliant
2 years (1 year Limited Warranty plus additional 1 year warranty is available on product registration)
Installation and connection of your HydroTap must be carried out by a qualied person, observing all local, state & federal regulations. You will require suitable 220 -240V 50/60Hz 15 amp power supply with a NEMA
6-15 electrical outlet within 3’ of the product. The HydroTap is an air-cooled system so discrete cabinetry cut-outs are required for ventilation. Installation on most counter tops is straightforward however some stone
counter tops may require a specialized cutting service. If using a drip tray (font) accessory suitable drainage to a trapped waste is required within 3’ of the installation. If you live in an area with hard water (more than
120ppm), we recommend installation of a scale ltration kit. Sufcient space and clearance to install the HydroTap as detailed in the product installation guidelines is required. Installation by Zip Professional Service
can be arranged with a phone call to 1-833-233-2358 or through www.us.zipwater.com
HYDROTAP
®
CLASSIC FOR OFFICE
*maximum ofce size = 60 people
A
A
1
8
SECTION A-A
3mm ( )
buffer pad
air space
(464
mm
)
18.3"
IEC Flex & Plug
230-240V, 50Hz
power outlet
Position the Tap to dispense into the sink
bowl with ample clearance for a cup or a carafe.
Alternatively, the Tap may be mounted away from
the sink using a Zip Font, available as an accessory.
Sample
Tap
Clearance
Envelope
Mains cold water
isolation valve
(not supplied)
1
8
8 "
(207
mm
)
DETAIL B: CABINET FLOOR CUT-OUT
VENTILATION DETAIL
See Detail B
240V
SINGLE
PHASE
POWER
240V
(333
mm
)
13.1"
min
7.9"
min
(200
mm
)
1 "
hole
Sink shown only
3
8
(35
mm
)
11
16
1
" max
15
16
12
"
(326
mm
)
3
16
"
(5
mm
)
(43
mm
)
2.0"
min
(50
mm
)
2.0"
min
(50
mm
)
15.5"
min
(394
mm
)
19ZIP016_ClassicOfceBC_240v_v1